Part Number
DEMIL
Shelf Life
UOM
NIIN
NSN
National Stock Number:
TXT
Description:
El Engine Starter Relay-solenoid
MRC:
A measurement taken at right angles to the length of the mounting slot,in distinction from thickness.ABTD
Mounting Slot Width:
0.281 inches
MRC:
A measurement of the longest dimension of the mounting slot,in distinction from width.ABVG
Mounting Slot Length:
0.344 inches
MRC:
An indication of whether or not an item is capable of operation while submerged.AHZV
Submersibility:
Nonsubmersible
MRC:
The distance between the mounting facilities.ARKQ
Mounting Facility Spacing:
1.747 in. Min 1.753 in. Maximum c to c
MRC:
The nominal value(s) of potential for which the item is rated.AWYG
Voltage Rating:
12.0 volts
MRC:
The voltage rating at which the item will close.AWZB
Closing Voltage Rating:
Between 7.0 volts and 9.0 volts
MRC:
The voltage rating at which the item will open.AXAY
Opening Voltage Rating:
Between 3.0 volts and 5.0 volts
MRC:
The amount of current required to activate the item.AXAZ
Pull-in Current:
Between 16.700 amperes and 19.500 amperes
MRC:
The amount of current required to maintain operation of the item.AXBA
Hold-in Current:
Between 2.1 amperes and 2.5 amperes
MRC:
The measured distance of the plunger stroke.AXBD
Plunger Stroke Length:
0.500 inches
MRC:
An indication of whether or not engaging linkage is included.AXBE
Engaging Linkage:
Included
MRC:
An indication of whether or not the linkage is adjustable.AXBG
Linkage Adjustability:
Adjustable
MRC:
Indicates the type of shift lever connection provided with the linkage.AXBH
Err Default:
Err default
MRC:
Indicates the type of shift lever connection provided with the linkage.AXBH
Linkage Shift Lever Connection Type:
Threaded rod
MRC:
An indication of whether or not the item includes provisions for manually closing the contacts.AXCC
Contact Manual Closing Provision:
Not included
MRC:
The number of control terminals provided.AXCD
Control Terminal Quantity:
2
MRC:
Indicates the type of control terminal/s/ provided.AXCE
Control Terminal Type:
Screw
MRC:
An indication of whether or not a grounded control terminal is included.AXCF
Grounded Control Terminal:
Included
MRC:
The number of main terminals provided.AXHJ
Main Terminal Quantity:
2
MRC:
Indicates the type of main terminal/s/ provided.AXHK
Main Terminal Type:
Stud
MRC:
The diameter of the motor for which the rigid mount is designed.AXHN
Motor Diameter For Which Rigid Mount Is Designed:
4.438 inches
MRC:
Indicates the type and number of facilities by which the item is mounted.AXHR
Mounting Facility Type And Quantity:
4 slot