Part Number 64A92C755-2

Capillary Indicating Thermometer

Pricing & Availability

Submit this form for current pricing and availability of this NSN.
Part / NSN:
Qty:
Your Email:
Phone:
Ref. / PO #:
Company:
Your Name:

We do not share or sell your information to anyone.
Privacy | Terms

All major credit cards accepted as well as gov. p-cards
Part Number
DEMIL
Shelf Life
UOM
NIIN
Part:
64a92c755-2
Demil:
No
Shelf Life:
UOM:
NIIN:
009461035

Part Information
Safety switch set to shut off at 205 degrees porm 2 deg

NSN
National Stock Number:
6685-00-946-1035 6685009461035
TXT
Description:
Capillary Indicating Thermometer
INC
INC
Item Name Code:
07419
MRC:
The length of a straight line which passes through the center of a case,and terminates at the circumference.ABKJ
Case Diameter:
2.190 inches
MRC:
A designation distinguishing one group of screw thread diameter-pitch combinations from another by the number of threads per measurement scale for a specific diameter on the mounting facility.AKEJ
Mounting Facility Screw Thread Series Designator:
Unf
MRC:
The length of a straight line which passes through the center of the dial,and terminates at the circumference.ASSP
Dial Diameter:
1.750 inches
MRC:
Indicates the type of scale.ATEQ
Scale Type:
Concentric dial
MRC:
The smallest value between the markings on a scale.AWAG
Scale Smallest Increment:
10.0 degrees fahrenheit
MRC:
Indicates the type and number of facilities by which the item is mounted.AXHR
Mounting Facility Type And Quantity:
1 stud and 1 bracket
MRC:
The hue or tint of the inscription(s) and/or that portion of the scale which surrounds the inscription on the scale.BGKZ
Scale Inscription/background Color:
White marking on black background
MRC:
Indicates the type of case provided.BHMC
Case Type:
Dustproof and vaporproof
MRC:
An indication of the medium used to actuate the item.BKCM
Actuating Medium:
Ethyl ether
MRC:
The amount of accuracy for which the scale is rated.BKCN
Scale Accuracy Rating:
1 pct
MRC:
The number of bulbs provided.BKCT
Bulb Quantity:
1
MRC:
Indicates the type of bulb provided with the item.BKCW
Bulb Type:
Plain rigid
MRC:
Indicates the type of bulb connection provided with the item.BKCX
Bulb Connection Type:
Threaded
MRC:
A measurement of the longest dimension of the active portion of an item,in distinction from width.BKCY
Active Portion Length:
1.530 inches
MRC:
The length of a straight line which passes through the center of the active portion of a circular figure or body,and terminates at the circumference.BKCZ
Active Portion Diameter:
0.360 inches
MRC:
The means used to connect the indicator.BLQF
Indicator Connection Method:
Flexible tube
MRC:
A measurement of the longest dimension of the flexible tube,in distinction from width.BLQG
Flexible Tube Length:
288.000 inches
MRC:
The number of mounting threads on the item measured on a line parallel to the thread axis,including incomplete threads.CGGK
Mounting Thread Quantity:
32 per inch
MRC:
The nominal length of a straight line which passes through the center of a coaxial cylinder which would bound the crest of an external thread or the root of an internal thread.CRYY
Mounting Facility Screw Thread Diameter:
0.190 inches
MRC:
None.CSYH
Bulblength:
1.530 inches
MRC:
Indicates the type and number of pointer(s) or pen(s).CSYJ
Pointer/pen Type And Quantity:
1 indicating single
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Copper bulb
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Steel meter case

Similar Capillary Indicating Thermometers

« Pressure, Temperature and Humidity Measuring and Controlling Instruments Catalog
Compare Now »
Clear | Hide