Part Number 6515NCM041229

Biologic Mechanical Refrigerator

Pricing & Availability

Submit this form for current pricing and availability of this NSN.
Part / NSN:
Qty:
Your Email:
Phone:
Ref. / PO #:
Company:
Your Name:

We do not share or sell your information to anyone.
Privacy | Terms

All major credit cards accepted as well as gov. p-cards
Part Number
DEMIL
Shelf Life
UOM
NIIN
Part:
6515ncm041229
Demil:
Shelf Life:
UOM:
NIIN:
016497356

Part Information
Refrigerator, blood bank double door, 720 units

NSN
National Stock Number:
4110-01-649-7356 4110016497356
TXT
Description:
Biologic Mechanical Refrigerator
INC
INC
Item Name Code:
15754
MRC:
An overall measurement between specified points of an item,in distinction from height.ABFY
Overall Depth:
35.50 inches
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
78.75 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
59.25 inches
MRC:
Indicates the type of current whether alternating,direct,or both.ACDC
Current Type:
Dc
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
60.0 hertz
MRC:
The universal medical device nomenclature system code for this item.ALUE
Universal Medical Device Nomenclature System Code:
15171
MRC:
The value(s) of potential for which the item is rated.AMSE
Voltage Rating:
115.0 volts
MRC:
The number of doors provided.ATSZ
Door Quantity:
2
MRC:
A measurement of the capacity of an item and its location.BBDY
Capacity And Location:
56.0 cubic feet storage
MRC:
Those unusual or unique characteristics or qualities of an item not covered in the other requirements and which are determined to be essential for identification.FEAT
Special Features:
Featgrefrigerator, blood bank double door; 720 units; 12 drawer w/casters; 115v/60hz; requires 15 amp dedicated ground circuit; mena 5-15 hospital grade plug (115v); certified to ul and csa standards, indoor use only; non corrosive, non-flammable, non-exploive, 15 degrees celcius to 32 degrees celcius; .5hp hermetic compressor, quantity: 1; automatic defrosting; r134a non-cfc refrigerant charge; led digiital temperature display, c or f; lockable door; power failure alarm; 9 volt non rechargeable battery backup for controller; swivel locking casters; 880 pounds
MRC:
Describes the capabilities,intended use,and/or purpose for which the item is provided.FTLD
Functional Description:
Blood bank applications