Part Number
DEMIL
Shelf Life
UOM
NIIN
Part:
666062-022
Demil:
Yes - DEMIL/MLI
Shelf Life:
UOM:
NIIN:
005709291
NSN
National Stock Number:
5999-00-570-9291 5999005709291
TXT
Description:
Delay Line
INC
INC
Item Name Code:
06373
INC
COM
Compliance:
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the body.AAQL
Body Style:
Cylindrical
MRC:
The length of a straight line which passes through the center of the body,and terminates at the circumference.ABPM
Body Diameter:
Between 0.469 inches and 0.531 inches
MRC:
A measurement of the longest dimension of the body,in distinction from width.ADAQ
Body Length:
Between 3.375 inches and 3.625 inches
MRC:
The number of individual sections included in the item.AFBH
Individual Section Quantity:
1
MRC:
The minimum and maximum limits of temperature at which the item is rated for operation.AFGA
Operating Tempurature Range:
-54.0/+85.0 degrees celsius
MRC:
Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
Inclosure Type:
Hermetically sealed
MRC:
The number of mounting facilities provided.AKPV
Mounting Facility Quantity:
2
MRC:
The value(s) of potential for which the item is rated.AMSE
Voltage Rating:
30.000 volts
MRC:
The total oppositon (resistive and reactive) which the item offers to the input flow of alternating current.ANSL
Input Impedance Rating:
2500.000 ohms
MRC:
The total opposition (resistive and reactive) which the item offers to the output flow of alternating current.ANSR
Output Impedance Rating:
2500.000 ohms
MRC:
The differences between limiting frequencies of a frequency band.APQL
Frequency Bandwidth:
1.3 hertz
MRC:
The facility for mounting the item.AZGM
Mounting Facility:
Clamp
MRC:
The means by which the signal is delayed.BZWM
Signal Delay Method:
Inductance
MRC:
The means used to vary the delay time of the item.CCDN
Delay Time Variation Method:
Tapped
MRC:
The time delay of each section of an item.CCDQ
Section Delay Time:
1.400 microseconds single section
MRC:
The number of segments into which a section is divided.CCDR
Segment Quantity Per Section:
6 single section
MRC:
The time delay of each segment.CCDS
Segment Delay Time:
0.100 microseconds single section all segments
MRC:
The rated time required for the pulse to rise.CCDX
Pulse Rise Time Rating:
0.300 microseconds
MRC:
Indicates the type and number of terminals for providing electrical connection.CCFF
Terminal Type And Quantity:
8 turret