Part Number
DEMIL
Shelf Life
UOM
NIIN
Part Information
Led p/n 11200009-1 mtd to holder assembly
NSN
National Stock Number:
TXT
Description:
Light Emitting Diode
MRC:
The element,compound,or mixture of which the inclosure is fabricated,excluding any surface treatment.ABBH
Inclosure Material:
Ceramic or glass or metal
MRC:
A measurement of the longest dimension of a terminal,in distinction from width.ABJT
Terminal Length:
Between 0.186 inches and 0.240 inches
MRC:
The specific purpose for which the item is designed.AFZC
Function For Which Designed:
Infrared emitting
MRC:
The number of mounting facilities provided.AKPV
Mounting Facility Quantity:
1
MRC:
The means of attaching the item.AXGY
Mounting Method:
Unthreaded hole
MRC:
Indicates the type of field force that could have detrimental effects on the serviceability of the device during normal handling or storage.BBJD
Field Force Effect Type:
Electrostatic charge
MRC:
The value of the voltage that may be applied,expressed in volts,and the symbol used to identify the specific electrical characteristic.CTQN
Voltage Rating In Volts Per Characteristic:
2.0 reverse voltage, peak
MRC:
The level of electrical flow and the symbol used to identify the specific electrical characteristic.CTQX
Current Rating Per Characteristic:
100.00 milliamperes source cutoff current absolute
MRC:
The hue,tint or shading produced by the item.CTRX
Color Tone Produced Per Source:
Infrared semiconductor
MRC:
The maximum temperature at which the item is designed to operate at each measurement point.CTSG
Maximum Operating Tempurature Per Measurement Point:
150.0 degrees celsius case
MRC:
The specification,standard,drawing,or similar instrument that specifies environmental and performance requirements or test conditions under which an item is tested and establishes acceptable limits within which the item must conform identified by an alphabetic and/or numeric reference number. includes the commercial and government entity (cage) code of the entity controlling the instrument.TEST
Test Data Document:
34860-11200009 drawing (this is the basic governing drawing, such as a contractor drawing, original equipment manufacturer drawing, etc.; excludes any specification, standard or other document that may be referenced in a basic governing drawing)
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
2 uninsulated wire lead