Part Number
DEMIL
Shelf Life
UOM
NIIN
NSN
National Stock Number:
TXT
Description:
Electrical Solenoid
MRC:
A numeric-alpha designator indicating the pitch diameter tolerance and an external or internal thread.AAJD
Thread Class:
2a plate coupling facility stud
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the body.AAQL
Body Style:
Armature end actuator
MRC:
The distance between the center of one mounting facility and the center of the adjacent mounting facility parallel to the length.ABKQ
Center To Center Distance Between Mounting Facilities Parallel To Length:
1.750 inches
MRC:
The length of a straight line which passes through the center of the body,and terminates at the circumference.ABPM
Body Diameter:
2.750 inches
MRC:
A measurement from the bottom to the top of the body,in distinction from depth.ADAU
Body Height:
1.500 inches
MRC:
The element,compound,or mixture of which the case is fabricated,excluding any surface treatment.ADTV
Case Material:
Steel
MRC:
Consists of plating,dip,and/or coating that cannot be wiped off. plating and/or coating is any chemical and/or metallic additive,electrochemical,or mild mechanical process which protects the surface of the case.ADTY
Case Surface Treatment:
Cadmium
MRC:
Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
Inclosure Type:
Partially enclosed, shell
MRC:
The number of magnetic coils provided.APAF
Magnetic Coil Quantity:
1
MRC:
Indicates the type of duty provided.APNP
Duty Type:
Continuous
MRC:
The position of the terminal/s/ for making connection to an item.APXH
Terminal Location:
Circumference
MRC:
The voltage rating at which the item is designed to operate,expressed in volts.ASXH
Voltage Rating In Volts:
12.0 dc
MRC:
Indicates the type and number of facilities by which the item is mounted.AXHR
Mounting Facility Type And Quantity:
2 threaded stud
MRC:
The number of threads on the item per linear inch measured on a line parallel to the thread axis.CMLP
Thready Qty Per Inch (tpi):
32 plate coupling facility stud
MRC:
The movement of the actuator when force is applied.CNXT
Actuator Stroke Type:
Rotary
MRC:
Indicates the type of means provided for connection of the power takeoff.CNXX
Power Takeoff Connection Type:
Plate coupling
MRC:
The plate coupling facility provided for attachment,and the number of each.CNYF
Plate Coupling Facility And Quantity:
3 threaded hole
MRC:
The length of a straight line which passes through the center of the plate coupling facility,and terminates at the circumference.CNYG
Plate Coupling Facility Diameter:
2.405 inches
MRC:
The distance from a center point of the plate coupling facility to an axis of rotation.CNYM
Plate Coupling Facility Radius:
0.938 inches
MRC:
The center to center spacing of the facilities on the plate coupling,expressed in degrees.CPBN
Plate Coupling Facility Center To Center Spacing In Deg:
120.0
MRC:
A designation that is used for the purpose of general identification of the thread.CQJX
Thread Size:
0.190 inches plate coupling facility stud
MRC:
The general configuration and relative position of the facilities provided for mounting the item.CQYJ
Mounting Facility Pattern:
Two position in-line
MRC:
The direction in which an item is designed to rotate,when viewed axially and the angular degree of travel from the de-energized to the energized position.CSQY
Rotation Direction And Energizing Stroke In Angular Deg:
40.0 counterclockwise
MRC:
A designation distinguishing one group of thread diameter-pitch combinations from another by the number of threads per measurement scale for a specific diameter.THSD
Thread Series Designator:
Unf plate coupling facility stud
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
1 wire lead