Part Number
DEMIL
Shelf Life
UOM
NIIN
Part:
68057
Demil:
No
Shelf Life:
UOM:
NIIN:
016061199

Part Information
Eaton ex rt 5kva

NSN
National Stock Number:
6130-01-606-1199 6130016061199
TXT
Description:
Uninterruptible Power Supply
INC
INC
Item Name Code:
67374
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
70.0 millimeters
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
44.4 millimeters
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
13.1 millimeters
MRC:
The number of input alternating current phase(s).ANPM
Input Phase:
Single 1st alternate operating power rqmt
MRC:
The number of input alternating current phase(s).ANPM
Input Phase:
Three 2nd alternate operating power rqmt
MRC:
The input value/s/,or range of values,for which the item is rated.APNX
Input Voltage Rating:
230.0 ac volts 1st alternate operating power rqmt
MRC:
The input value/s/,or range of values,for which the item is rated.APNX
Input Voltage Rating:
400.0 ac volts 2nd alternate operating power rqmt
MRC:
The output value/s/,or range of values,for which the item is rated.APPA
Output Voltage Rating:
1000.0 ac volts single power output
MRC:
The number of complete cyclic changes,per unit of time,for which the input is rated.APTQ
Input Frequency Rating:
40.0 hertz and 70.0 hertz 1st alternate operating power rqmt
MRC:
The ambient temperature range at which the item is designed to operate.AYNH
Operating Ambient Tempurature Range:
-45.0 to 40.0 degrees celsius
MRC:
The output current rating at which the item is designed to operate.CWGH
Output Current Rating:
100.0 dc amperes single power output
MRC:
The emergency operating time a battery power supply can deliver full rated output voltage/current before the output drops below a specified value.CXMX
Battery Power Supply Emergency Operating Time:
8.0
MRC:
Those unusual or unique characteristics or qualities of an item not covered in the other requirements and which are determined to be essential for identification.FEAT
Special Features:
Three phase; output power: 4000w; floor standing; connectors: rj-11; automatic shutdown; weight: 24.17kg; double conversion (on-line) high performance ups for single phase applications; hot swappable ups and battery modules