Part Number
DEMIL
Shelf Life
UOM
NIIN
Part Information
Calibrated timing dial front screw terminals 8-32 truss head screws, potted coil, ambient temp range of m67 degrees f to p165 degrees f., auxiliary switch provided
NSN
National Stock Number:
TXT
Description:
Relay-switch
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
3.250 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
5.760 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
3.090 inches
MRC:
Indicates the type of switch included in the item.AEEA
Switch Type:
Pressure
MRC:
The pattern or arrangement that describes the mounting configuration of the item.ALGC
Mounting Configuration:
Vertical mounting, front or back, or horizontal mounting, 4 tapped holes on back plate
MRC:
Indicates the type of action provided.AMWM
Action Type:
Time delay
MRC:
Indicates the type of relay/s/ provided.APCL
Relay Type:
Time delay
MRC:
Indicates the type of current used with the contact/s/.APFX
Contact Current Type:
Ac and dc
MRC:
The maximum voltage rating at which the item is designed to operate,expressed in volts.APFY
Maximum Voltage Rating In Volts:
480.0
MRC:
The amount of current at maximum rated voltage for which the item is designed.APGW
Current Rating At Maximum Rated Voltage:
10.0 amperes resistive
MRC:
The maximum amount of current for which the item is designed,expressed in amperes.APGX
Maximum Current Rating In Amps:
20.0 resistive
MRC:
The amount of voltage for which the item is designed to withstand at the maximum rated current.APGY
Voltage Rating At Maximum Rated Current:
240.0 volts
MRC:
Indicates the type of current for which the coil is designed.APGZ
Coil Current Type:
Dc
MRC:
The amount of operating voltage,expressed in volts.APHA
Operating Voltage In Volts:
Between 200.0 and 300.0
MRC:
The amount of time required for tripping the item,expressed in seconds.APMG
Tripping Time In Seconds:
1.0
MRC:
The designation that identifies the schematic diagram of the contact configuration.CPWK
Contact Arrangement:
1dpdt