Part Number 703M

Laboratory Oven

Pricing & Availability

Submit this form for current pricing and availability of this NSN.
Part / NSN:
Qty:
Your Email:
Phone:
Ref. / PO #:
Company:
Your Name:

We do not share or sell your information to anyone.
Privacy | Terms

All major credit cards accepted as well as gov. p-cards
Part Number
DEMIL
Shelf Life
UOM
NIIN
Part:
703m
Demil:
Yes - DEMIL/MLI
Shelf Life:
UOM:
NIIN:
001655751
NSN
National Stock Number:
6640-00-165-5751 6640001655751
TXT
Description:
Laboratory Oven
INC
INC
Item Name Code:
17096
INC
COM
Compliance:
MRC:
Indicates the type of current whether alternating,direct,or both.ACDC
Current Type:
Ac
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
60.0 hertz
MRC:
An outside measurement taken at right angles to the length of an item,in distinction from thickness.ADJV
Outside Width:
25.000 inches
MRC:
An outside measurement from the bottom to the top of an item,in distinction from depth.AFMW
Outside Height:
36.000 inches
MRC:
The value(s) of potential for which the item is rated.AMSE
Voltage Rating:
230.0 volts
MRC:
The amount of electrical energy that can be dissipated.ANPT
Power Rating:
3.2 kilowatts
MRC:
The minimum and maximum operating temperatures at which the item is rated,expressed in degrees celsius.ASQJ
Operating Tempurature Range In Deg Celsius:
+35.0/+325.0
MRC:
The minimum and maximum operating temperatures at which the item is rated,expressed in degrees celsius.ASQJ
Operating Tempurature Range In Deg Celsius:
+35.0 to 325.0
MRC:
The heat source for which the item is designed.AZZH
Heat Source For Which Designed:
Integral
MRC:
An outside measurement between specified points on an item,in distinction from height.BCXB
Outside Depth:
23.000 inches
MRC:
The means by which the item is heated.BDWT
Heating Method:
Electrical
MRC:
An indication of whether or not the item is provided with a water jacket.BGXH
Water Jacket:
Not provided
MRC:
The number of shelves furnished with the item.BGZL
Shelf Quantity:
2
MRC:
The means used to provide circulation.BHGT
Circulation Method:
Forced air
MRC:
An indication of whether or not an insulated cabinet is provided.BLST
Insulated Cabinet:
Provided
MRC:
The element,compound,or mixture of which the shelf is fabricated,excluding any surface treatment.BPYK
Shelf Material:
Steel, corrosion resisting
MRC:
The element,compound,or mixture of which the cabinet outer wall is fabricated,excluding any surface treatment.BQMH
Cabinet Outer Wall Material:
Steel, corrosion resisting
MRC:
The element,compound,or mixture of which the cabinet inner wall is fabricated,excluding any surface treatment.BQMJ
Cabinet Inner Wall Material:
Steel, corrosion resisting
MRC:
The number of outer doors included.BQMN
Outer Door Quantity:
1
MRC:
The element,compound,or mixture of which the outer door is fabricated,excluding any surface treatment.BQMP
Outer Door Material:
Steel, corrosion resisting
MRC:
An indication of whether or not an outer door insulation feature is included.BQMR
Outer Door Insulation Feature:
Included
MRC:
An indication of the characteristic(s) of the material.BQWH
Material Characteristic:
Grid
MRC:
An indication of whether or not a vacuum chamber is included.BQWN
Vacuum Chamber:
Included
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the vacuum chamber.BQWP
Vacuum Chamberlength:
20.000 inches
MRC:
The length of a straight line which passes through the center of the vacuum chamber,and terminates at the inside circumference.BQWQ
Err Default:
Err default
MRC:
The length of a straight line which passes through the center of the vacuum chamber,and terminates at the inside circumference.BQWQ
Vacuum Chamber Inside Diameter:
28.280 inches
MRC:
An indication of whether or not the vacuum chamber is removable.BQWR
Vacuum Chamber Removability:
Nonremovable
MRC:
The number of alternating current phases.FAAZ
Phase:
Single

Similar Laboratory Ovens

« Laboratory Equipment and Supplies Catalog
Compare Now »
Clear | Hide