Part Number
DEMIL
Shelf Life
UOM
NIIN
Part Information
Adhesive sealant applied to each end
NSN
National Stock Number:
TXT
Description:
S Electrical Insulation Sleeving
MRC:
An indication that the level of probability that an item will operate without failure,at a specified rated capability,at a specified temperature,and for a specified period of time,has been established by testing random samples of production lot.AARG
Reliability Indicator:
Not established
MRC:
The environmental elements or conditions that an item is designed or protected to resist or withstand satisfactorily.ADZC
Environmental Protection:
Corrosion resistant and flame resistant and mildew resistant and solvent resistant and water resistant
Distance From Centerline Of Main Body To End Of First Branch:
1.500 inches after unrestricted recovery
Distance From Centerline Of Main Body To End Of First Branch:
Any acceptable as supplied
Main Body Inside Diameter:
0.600 inches after unrestricted recovery
Main Body Inside Diameter:
1.200 inches as supplied
First Branch Inside Diameter:
0.400 inches after unrestricted recovery
First Branch Inside Diameter:
0.800 inches as supplied
Main Body Wall Thickness:
0.100 inches after unrestricted recovery
Main Body Wall Thickness:
Any acceptable as supplied
First Branch Wall Thickness:
0.080 inches after unrestricted recovery
First Branch Wall Thickness:
Any acceptable as supplied
Main Bodylength:
3.250 inches after unrestricted recovery
Main Bodylength:
Any acceptable as supplied
Angle Between Main Body And First Branch Centerlines In Deg:
165.0 as supplied
Angle Between Main Body And First Branch Centerlines In Deg:
90.0 after unrestricted recovery
MRC:
The maximum rated load in tension applied in a longitudinal direction,per unit of cross-sectional area,that the material can withstand without rupture.CQBC
Min. Tensile Strength (psi):
1500 pounds per square inch
MRC:
Flexible,capable of being bent,turned or twisted,within limits,without breaking,or rigid,resisting change of form,inflexible.FLEX
Flexibility:
Semirigid
MRC:
A characteristic of light that can be specified in terms of luminance,dominant wavelength,and purity.HUES
Color:
Black
MRC:
The element,compound,or mixture of which an item is fabricated,excluding any surface treatment.MATL
Material:
Plastic, polyolefin, rt-301, raychem corp
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Plastic, polyolefin, rt-301, raychem corp
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the item.STYL
Style Designator:
Transition-t
MRC:
The maximum potential gradient the insulating material can withstand,per unit thickness,without rupture.UKBG
Dielectric Material Voltage Rating Per Unit Thickness:
200.0 volts per military /0.001 inch/