Part Number
DEMIL
Shelf Life
UOM
NIIN
Part Information
Used w/low pressure sodium lamps, ansi l-73 and l-74; high reactance-power factor corrected; includes core and coil w/oil filled capacitor
NSN
National Stock Number:
TXT
Description:
Lamp Ballast
MRC:
The number of terminals for providing electrical connection to the item.AARA
Terminal Quantity:
5
MRC:
Indicates the type of terminals for providing electrical connection to the item.AARB
Terminal Type:
Wire lead
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
5.750 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
4.250 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
4.000 inches
MRC:
The number of mounting holes provided.ABTJ
Mounting Hole Quantity:
10
MRC:
Indicates the type of current whether alternating,direct,or both.ACDC
Current Type:
Ac
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
60.0 hertz
MRC:
A measurement of the center to center distance between the mounting holes along the length.ADHV
Center To Center Distance Between Mounting Holes Along Length:
5.375 inches
MRC:
The means of attaching the item.ADJH
Mounting Method:
Holes
MRC:
The number of lamps that can be accommodated by the item.AEUH
Lamp Accommodation Quantity:
1
MRC:
The rated power that a lamp can safely consume or provide,measured in watts.AEWS
Lamp Wattage Rating In Watts:
135.0 and 180.0
MRC:
The electrical current rating,expressed in amperes.AMPS
Current Rating In Amps:
2.300 or 2.900
MRC:
The value(s) of potential for which the item is rated.AMSE
Voltage Rating:
Between 208.0 volts and 277.0 volts
MRC:
The characteristic of the power factor.ARGL
Power Factor Characteristic:
Low
MRC:
The starting characteristic of the item.ARQF
Starting Characteristic:
Preheat
MRC:
An indication of whether or not a starter is required.ARQG
Starter:
Not required
MRC:
The position and quantity of terminals for making connection to the item.ARQH
Terminal Location And Quantity:
3 one end and 2 other end
MRC:
A designation which indicates the shape and size of the bulb.CSJW
Bulb Designator:
L-73
MRC:
The form,construction,or type of lamp which distinguishes it from other like items that the item will accommodate.CWAD
Lamp Type Accommodated:
Energy efficient