Part Number
DEMIL
Shelf Life
UOM
NIIN
Part Information
Junction pattern arrangement: pnp
NSN
National Stock Number:
TXT
Description:
Transistor
MRC:
The element,compound,or mixture of which the inclosure is fabricated,excluding any surface treatment.ABBH
Inclosure Material:
Metal
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
0.225 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
0.100 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
0.155 inches
MRC:
An indication of the internal basic form of the item.ALAS
Internal Configuration:
Junction contact
MRC:
The means of attaching the item.AXGY
Mounting Method:
Press fit
MRC:
Those features,not otherwise specified,which may be required for proper functioning of the item.CBBL
Features Provided:
Hermetically sealed case and electrostatic sensitive
MRC:
The chemical compound or mechanical mixture properties of which the semiconductor is fabricated.CTMZ
Semiconductor Material:
Germanium
MRC:
The value of the voltage that may be applied,expressed in volts,and the symbol used to identify the specific electrical characteristic.CTQN
Voltage Rating In Volts Per Characteristic:
30.0 collector to base voltage, dc and 15.0 collector to emitter voltage/static/base open
MRC:
The level of electrical flow and the symbol used to identify the specific electrical characteristic.CTQX
Current Rating Per Characteristic:
5.00 milliamperes source cutoff current
MRC:
The amount of electrical power that can be dissipated and the specific electrical characteristic.CTRD
Power Rating Per Characteristic:
100.0 milliwatts small-signal input power, common-collector preset
MRC:
The ratio of the input electrical signal to the output electrical signal at specified operating conditions.CTRK
Transfer Ratio:
10.0 static forward current transfer ratio, common-emitter
MRC:
The maximum temperature at which the item is designed to operate at each measurement point.CTSG
Maximum Operating Tempurature Per Measurement Point:
150.0 degrees celsius junction
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
4 uninsulated wire lead