Part Number
DEMIL
Shelf Life
UOM
NIIN
NSN
National Stock Number:
TXT
Description:
Fluid Pressure Regulating Valve
MRC:
The basic material of which the body is fabricated.AAFZ
Body Material:
Bronze
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the body.AAQL
Body Style:
Straight thru
MRC:
The element, compound,or mixture of which the stem is fabricated,excluding any surface treatment.ABEP
Stem Material:
Bronze
MRC:
The type of service with which the item is designed to be used.ACKL
Media For Which Designed:
Air
MRC:
A narrative description of the type of end connection.ACKM
First End Connection Type:
Threaded internal pipe
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the end.ACKN
First End Style Designator:
Plain
MRC:
Designates the thread diameter,series/type,and number of threads per specific measurement scale.ACLJ
First End Thread Size And Series/type Designator:
1/2-14 npt
MRC:
The direction of the thread when viewed axially. a right-hand thread winds in a clockwise direction while a left-hand thread winds in a counterclockwise direction.ACLL
First End Thread Direction:
Right-hand
MRC:
Indicates whether or not the second end is identical to the first end.ACLR
Second End Relationship With First End:
Identical
MRC:
The element,compound,or mixture of which the seating surfaces are fabricated.ACSH
Seat Material:
Bronze
MRC:
The part that controls the flow through the item.ADQU
Flow Control Device:
Stem and integral disk
MRC:
The element,compound,or mixture of which the flow control device is fabricated.ADQV
Flow Control Device Material:
Bronze and brass
MRC:
The number of end connections included in the item.ADQZ
End Connection Quantity:
2
MRC:
The seat design of the valve stem.AEVQ
Valve Stem Design:
Double seat
MRC:
The means whereby a valve is actuated other than by the media passing through it.AEVS
Remote Actuation Method:
Piston
MRC:
The maximum pressure of the media on the inlet side at which an item is designed to operate.AEVZ
Maximum Inlet Pressure Rating:
125.0 pounds per square inch
MRC:
The set /nonadjustable/ pressure of the media on the outlet side.AEWA
Outlet Pressure Setting:
25.0 pounds per square inch
MRC:
A value which expresses the degree of heat or cold as applied to the operation,or limitation of operation,of an item.AZKQ
Tempurature Rating:
175.0 degrees fahrenheit