Part Number 746-245

Thermal Relay

Pricing & Availability

Submit this form for current pricing and availability of this NSN.
Part / NSN:
Qty:
Your Email:
Phone:
Ref. / PO #:
Company:
Your Name:

We do not share or sell your information to anyone.
Privacy | Terms

All major credit cards accepted as well as gov. p-cards
Part Number
DEMIL
Shelf Life
UOM
NIIN
Part:
746-245
Demil:
No
Shelf Life:
UOM:
NIIN:
002546271

Part Information
Mounts by two clearance holes for no. 10 screws spaced 1.375 inches c to c

NSN
National Stock Number:
5945-00-254-6271 5945002546271
TXT
Description:
Thermal Relay
INC
INC
Item Name Code:
03883
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
5.000 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
1.500 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
2.000 inches
MRC:
The designation that identifies the schematic diagram of the contact configuration.APFR
Contact Arrangement:
Single pole, single throw, normally open
MRC:
Indicates the type and number of facilities by which the item is mounted.AXHR
Mounting Facility Type And Quantity:
2 threaded hole
MRC:
The highest voltage at which the contacts are rated for normal operating,expressed in volts.CYCS
Contact Maximum Voltage Rating In Volts:
115.0 ac
MRC:
The highest current at which the contacts are rated for normal operation,expressed in amps.CYCT
Contact Maximum Current Rating In Amps:
1.0 ac
MRC:
The amount of voltage for which the heater is designed,expressed in volts.CYCU
Heater Voltage Rating In Volts:
115.0
MRC:
A numeric value indicating the elapsed time interval of the item,expressed in seconds.CYCW
Delay Time In Seconds:
Between 35.0 adjustable operate and 45.0 adjustable operate

Similar Thermal Relaies

« Relays and Solenoids Catalog
Compare Now »
Clear | Hide