Part Number 76-602-115E137

Pyrometer And Thermocoupl Tester

Pricing & Availability

Submit this form for current pricing and availability of this NSN.
Part / NSN:
Qty:
Your Email:
Phone:
Ref. / PO #:
Company:
Your Name:

We do not share or sell your information to anyone.
Privacy | Terms

All major credit cards accepted as well as gov. p-cards
Part Number
DEMIL
Shelf Life
UOM
NIIN
Part:
76-602-115e137
Demil:
No
Shelf Life:
UOM:
NIIN:
010444966

Part Information
Dry well temp chamber 1 inch diameter by 6 inches deep; direct reading digital thumbwheel switch control; sensor platinum resistance thermometer; solid state electronics; insert type adapter chucks made of plated copper; 1300 degrees f thermal fuse; input power 115 vac, 50/60 hz; 4 adapter chucks sizes 1/4, 3/8, 7/16, and 9/16 inch bore diameter

NSN
National Stock Number:
6685-01-044-4966 6685010444966
TXT
Description:
Pyrometer And Thermocoupl Tester
INC
INC
Item Name Code:
07344
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
13.250 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
12.500 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
9.750 inches
MRC:
An indication of the manner in which the scale is calibrated.AMNK
Scale Calibration:
Portable dry well temperature calibrator
MRC:
The installation for which the item is designed.AMQY
Installation Design:
Portable
MRC:
An indication of the scale range.APSK
Scale Range:
+100.0/+1200.0 degrees fahrenheit
MRC:
Indicates the type of measurement provided.BFHZ
Measurement Type:
Bridge circuit
MRC:
The degree of conformity of a scale measurement to a standard or a true value.BGKS
Scale Accuracy:
1 degrees f to 600 degrees f, 0.2% of set point above 600 degrees f
MRC:
Indicates the type of case provided.BHMC
Case Type:
Hinged lid carrying case w/handle
MRC:
Describes the capabilities,intended use,and/or purpose for which the item is provided.FTLD
Functional Description:
Self contained temp test system used to test a variety of temp instruments in the range of 100 degrees f to 1200 degrees f; tests and calibrates thermocouples, thermal switches, thermistors, temp control systems and temp indicators
MRC:
Characteristics or qualities of an item,not covered in any other requirement,which are considered essential information for one or more functions excluding nsn assignment.SUPP
Supplementary Features:
Manufacturers name: portable dry well temperature calibration system