Part Number
DEMIL
Shelf Life
UOM
NIIN
NSN
National Stock Number:
TXT
Description:
Pre Wire Wound Variable Resistor
MRC:
The number of individual elements.AAPN
Section Quantity:
2
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the body.AAQL
Body Style:
Cylindrical servo mounted
MRC:
An indication that the level of probability that an item will operate without failure,at a specified rated capability,at a specified temperature,and for a specified period of time,has been established by testing random samples of production lot.AARG
Reliability Indicator:
Not established
MRC:
The length of a straight line which passes through the center of that portion used to guide the item and terminates at the circumference.AAVL
Pilot Diameter:
Between 1.18600 inches and 1.18700 inches
MRC:
The length of the pilot,which is the unthreaded portion beyond the thread used to guide the item.AAVM
Pilot Length:
0.05700 inches
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
1.687 inches
Undercut Diameter:
1.24000 inches
Undercut Width:
0.05700 inches
MRC:
The length of a straight line which passes through the center of the body,and terminates at the circumference.ABPM
Body Diameter:
Between 1.302 inches and 1.312 inches
MRC:
The length of a straight line which passes through the center of a shaft,and terminates at the circumference.ABWV
Shaft Diameter:
Between 0.249 inches and 0.250 inches
MRC:
A measurement of the longest dimension of the shaft,in distinction from width.ABXF
Shaft Length:
0.562 inches
MRC:
A measurement of the longest dimension of the body,in distinction from width.ADAQ
Body Length:
1.135 inches
MRC:
A measurement of the longest straight line across a circular cross-sectional plane.ADAV
Overall Diameter:
1.386 inches
Mounting Lip Diameter:
Between 1.30200 inches and 1.31200 inches
Mounting Lip Depth:
Between 0.05700 inches and 0.06700 inches
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the shaft.AEDX
Shaft Style:
Round
MRC:
Indicates the type of switch included in the item.AEEA
Switch Type:
Rotary
MRC:
The voltage for which the switch is rated for normal operation,expressed in volts.AEED
Switch Voltage Rating In Volts:
25.0
MRC:
Indicates the type of facility or arrangement provided for moving the variable contact(s).AEFD
Actuator Type:
Single shaft
MRC:
That part of the total rotational travel of the actuator that produces a change in output,expressed in degree angular rotation.AEFH
Effective Electrical Rotation In Deg Angular Rotation:
100.0
MRC:
The definitive positional point at which the switch operates /starting with the actuator in extreme counterclockwise position and moving clockwise for rotary actuated resistors;starting with actuator full retracted /pushed in/ for longitudinally actuated resistors/.AEGH
Switch Operating Position:
Start of rotation
MRC:
A designation that describes the basic electrical configuration of a switch.AEGJ
Switch Contact Arrangement:
Single pole, single throw, normally open, both positions maintained
MRC:
The position of the terminal/s/ for making connection to an item.APXH
Terminal Location:
Radially positioned over less than half the circumference
MRC:
The means of attaching the item.AXGY
Mounting Method:
Clamp ring
MRC:
A measure of the opposition to the flow of direct or alternating current per section.CQCC
Electrical Resistance Per Section:
5.000 kilohms single section
MRC:
The location per section,in degrees,of effective electrical rotation between the counterclockwise terminal of a resistor and each tap terminal.CQCH
Tap Location From Ccw Terminal Per Section In Deg Of Effective Electrical Rotation:
35.0 1st section
MRC:
The location per section,in degrees,of effective electrical rotation between the counterclockwise terminal of a resistor and each tap terminal.CQCH
Tap Location From Ccw Terminal Per Section In Deg Of Effective Electrical Rotation:
45.0 2nd section
MRC:
The location per section,in degrees,of effective electrical rotation between the counterclockwise terminal of a resistor and each tap terminal.CQCH
Tap Location From Ccw Terminal Per Section In Deg Of Effective Electrical Rotation:
55.0 3rd section
MRC:
The measurement of the rotary mechanical motion of the actuating shaft of an item,expressed in degrees.CQCK
Rotary Actuator Travel In Angular Deg:
100.0
MRC:
The permissible range per section by which the actual value of resistance or voltage at any specified point may deviate from the theoretical value for the linear or nonlinear function,expressed as a minus and plus percent.CQFL
Function Conformity Tolerance Per Section:
-1.00/+1.00 single section
MRC:
The ambient temperature at which the power dissipation of each section is derated to zero percent of the full rated power.CQGN
Ambient Tempurature In Deg Celsius Per Section At Zero Percent Rated Power:
110.0 single section
MRC:
The maximum amount of electrical energy that can be expended per section,expressed in watts.CRGD
Power Dissipation Rating Per Section In Watts:
2.0 free air single section
MRC:
The fidelity of the relationship between the actual function characteristics and the theoretical function per section.CRGM
Function Conformity Per Section:
Single section independent linearity
MRC:
The number of fixed terminals at points between the end terminals that provide connection to the intermediate values of the total value per section.CRJS
Fixed Tap Quantity Per Section:
3 single section
MRC:
The limits of permissible variation from the rated value of the location of a tap per section.CRKS
Tap Location Tolerance Per Section:
-1.0/+1.0 degrees angular rotation single section
MRC:
The limits of permissible variation in the electrical resistance value per section of an item from its rated value,expressed in percent.CRSS
Resistance Tolerance Per Section In Percent:
-5.0/+5.0 single section
MRC:
The feature that controls the actuator travel.CRSX
Actuator Travel Control Feature:
Stops
MRC:
The specified mathematical relation per section between the terminal resistance,or output ratio,and the rotation of the actuator.CSBX
Function Characteristic Per Section:
Single section linear
MRC:
The ambient temperature,expressed in degrees celsius,of the medium surrounding each section at which it can be operated continuously at full rated power.CSDH
Ambient Tempurature In Deg Celsius Per Section At Full Rated Power:
40.0 single section
MRC:
Indicates the type of electrical current and the capacity for normal operation of the switch,expressed in amperes.CSDK
Switch Current Type And Rating In Amps:
0.200 dc
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
6 tab, solder lug