Part Number
DEMIL
Shelf Life
UOM
NIIN
Part Information
Anesthesia apparatus gas 4 stand cylinder qty with carrying case
NSN
National Stock Number:
TXT
Description:
Gas Anesthesia Apparatus
MRC:
An indication of whether or not a container from which the item is completely removable in normal operable condition is provided.AFJU
Carrying Case:
Provided
MRC:
An indication of whether or not the item is furnished with a handle.AFYG
Handle:
Not furnished
MRC:
The name and number of those parts furnished with the item of supply that have not been specified elsewhere.AKYN
Furnished Items And Quantity:
Adapter, elbow, 1; bellows, hand operated, 1; gasket, 8; heater, electric, 1; mask, large, 1; mask, medium-adult, 1; tray, instrument, 1; valve, oxygen-flush, 1; valve, pressure, 1; wrench, open-end, 1; wrench, tee-handle
MRC:
An indication of whether or not a locking device is included.AMDA
Locking Device:
Not included
MRC:
The installation for which the item is designed.AMQY
Installation Design:
Portable
MRC:
The number of cylinders accommodated in the stand.CLQQ
Err Default:
Err default
MRC:
The number of cylinders accommodated in the stand.CLQQ
Stand Cylinder Quantity Accommodated:
4
MRC:
Designates the maximum cylinder size the item is designed to accommodate.CLQR
Err Default:
Err default
MRC:
Designates the maximum cylinder size the item is designed to accommodate.CLQR
Maximum Cylinder Size Accommodated:
E
MRC:
The means by which the gas head is mounted to the stand.CLQW
Err Default:
Err default
MRC:
The means by which the gas head is mounted to the stand.CLQW
Gas Head To Stand Mounting Method:
Folding stand by pivot pin w/manual lock
MRC:
The number of flowmeters provided on the item.CLQZ
Err Default:
Err default
MRC:
The number of flowmeters provided on the item.CLQZ
Flowmeter Quantity:
3
MRC:
The number of carbon dioxide absorption chambers provided.CLRB
Err Default:
Err default
MRC:
The number of carbon dioxide absorption chambers provided.CLRB
Carbon Dioxide Absorption Chamber Quantity:
2
MRC:
The number of pressure gages provided.CLRC
Err Default:
Err default
MRC:
The number of pressure gages provided.CLRC
Pressure Gage Quantity:
5
MRC:
The number of single yokes provided.CLRD
Err Default:
Err default
MRC:
The number of single yokes provided.CLRD
Single Yoke Quantity:
4
MRC:
An indication of whether or not a manometer is included.CLRG
Err Default:
Err default
MRC:
An indication of whether or not a manometer is included.CLRG
Manometer:
Not included
MRC:
Those unusual or unique characteristics or qualities of an item not covered in the other requirements and which are determined to be essential for identification.FEAT
Special Features:
For open, semi-closed, or closed method; for use with size d or e flush valve gas cylinder or large size gas cylinder; with cartridge-type-carbon dioxide absorber; carrying case with casters; supplied without cylinders; for carbon dioxide absorber cartridge; order soda lime, 6505-00-782-6484, for inhaler unit, order 6515-00-890-1685; for replacement parts, bag, rebreathing, 6515-00-476-5239 and 6515-01-045-3341, mask, oronasal, 6515-00-347-2200 and 6515-00-299-8297, tube, inhaler, 6515-00-302-1500; metered gas circuit break; nitrous oxide, oxygen, ether and cyclopropane
MRC:
Characteristics or qualities of an item,not covered in any other requirement,which are considered essential information for one or more functions excluding nsn assignment.SUPP
Supplementary Features:
Item has a potentially recoverable precious metal content