Part Number
DEMIL
Shelf Life
UOM
NIIN
Part Information
Power supply, din rail 24 vdc, 10 a, single output
NSN
National Stock Number:
TXT
Description:
Power Supply
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
138.0 millimeters
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
103.0 millimeters
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
114.0 millimeters
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
Cp140 flight simulator
MRC:
The input value/s/,or range of values,for which the item is rated.APNX
Input Voltage Rating:
85.0 ac volts single operating power rqmt and 264.0 ac volts single operating power rqmt and 90.0 dc volts single operating power rqmt and 350.0 dc volts single operating power rqmt
MRC:
The output value/s/,or range of values,for which the item is rated.APPA
Output Voltage Rating:
24.0 dc volts single power output and 26.4 dc volts single power output
MRC:
The ambient temperature range at which the item is designed to operate.AYNH
Operating Ambient Tempurature Range:
-40.0/+60.0 degrees celsius
MRC:
The rated output power that an item can safely consume or provide,measured in watts.BGQR
Output Wattage Rating:
240.0 watts single power output
MRC:
The output current rating at which the item is designed to operate.CWGH
Output Current Rating:
10.0 dc amperes single power output
MRC:
The maximum alternating current voltage variation which may be present on the direct current output voltage level.CWGZ
Ripple Voltage At Full Load:
0.42 volts rms single power output
MRC:
The amount of input current for which the item is rated.CWHM
Input Current Rating:
2.5 ac amperes single operating power rqmt and 1.3 dc amperes single operating power rqmt
MRC:
Those unusual or unique characteristics or qualities of an item not covered in the other requirements and which are determined to be essential for identification.FEAT
Special Features:
Input fuse 6.3 a slow; function indicator led, green; efficiency, ac 230 v, 89 pct; deviation static load change 350 mv; deviation dynamic load change 10-90 pct 2.6-3.0 v; peak to average ripple factor 5 pct; output hold up time 15 ms; output protection measures overload and short circuit protection; dielectric strength input/output ac 3 kv; operating mode 100 pct continuous duty; relative humidi type 93 pct no condensation; storage temperature m40.0-p100.0 degrees c; mounting system to be snapped onto din rail in accordance with en 50022, for vertical mounting, modular