Part Information
Front panel controls: prime power on/off, rf operate/standby (fault reset). Front panel indicators: prime power on/standby, rf operate, fault. Metering: helix current. Protection: prime power fuse, warm up delay, automatic sequencing of high voltage and beam current, unattended protection (heater shutdown after fault counter trip), helix current overload, high temperature low/high line voltage, safety interlocks. Equipment case, is a self-contained designed for bench top or rack mount. Auto recycle if power outage is lessthan 3 seconds. Automatic turn off if two consecutive helix overload faults occur: noise figure 35db max: spurious modulation m50dbc max: load vswr 2.5: 1 max: gain stabili type 0.25db/24hrs: maxoperating humidi type 95pct
NSN
National Stock Number:
TXT
Description:
Radio Frequency Amplifier
MRC:
The element,compound,or mixture of which the inclosure is fabricated,excluding any surface treatment.ABBH
Inclosure Material:
Aluminum
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
21.240 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
3.500 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
18.240 inches
MRC:
The minimum and maximum limits of temperature at which the item is rated for operation.AFGA
Operating Tempurature Range:
+0.0/+50.0 degrees celsius
MRC:
A measurement of volume taken by multiplying the length by the width by the height of an item and rendered in cubic units.AFJK
Cubic Measure:
0.733 cubic feet
MRC:
A term used to denote the specific measurement of duration used to indicate the average life of the item.AFSU
Average Life Measurement:
Not rated
MRC:
The style designation indicating the configuration that most nearly corresponds to the basic appearance of the item.AGTA
Basic Shape Style:
Rectangular or square
MRC:
The maximum altitude at which the item is rated to function.AKAE
Maximum Operating Altitude Rating:
10000.0 feet
MRC:
Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
Inclosure Type:
Encased
MRC:
The means by which the item is operated or controlled.ALBM
Operating Control Method:
Manual
MRC:
The installation for which the item is designed.AMQY
Installation Design:
Top of cabinet/counter and rack
MRC:
Indicates the type of control.AQZF
Control Type:
Local
MRC:
Indicates the type of circuit construction provided in the item.BHSX
Circuit Construction Type:
Solid state
MRC:
The portion of the frequency spectrum at which an item is designed to receive or transmit signal power.BHTB
Frequency Per Channel:
4.0 gigahertz operating channel err-100 and 8.0 gigahertz operating channel err-100
MRC:
The rated average power for each channel.BHTJ
Average Power Rating Per Channel:
10.0 watts output
MRC:
The increase in energy from the input to the output.BHTL
Overall Gain:
30.0 decibels
MRC:
Indicates the type of connection and its location on the item.BJBP
Connection Type And Location:
Receptacle, coaxial front
MRC:
The cycles per second /hertz/ of the operating alternating current.BJBQ
Operating Ac Frequency In Hertz:
47.0 single voltage and 63.0 single voltage
MRC:
The maximum power drain for which the item is rated.BJBR
Maximum Power Drain Rating:
250.0 watts
MRC:
Indicates the type and number of contact(s) included in the connection.BJBW
Connection Contact Type And Quantity:
1 receptacle, coaxial internal
MRC:
The value(s) of the potential supplied from an exterior alternating current source to operate the item,expressed in volts.BKFC
External Ac Operating Voltage In Volts:
99.0 single voltage and 132.0 single voltage
MRC:
The number of alternating current phases.FAAZ
Phase:
Single
MRC:
Indicates the relationship,such as construction,capabilities,and the like,of the item to a similar item.RTSE
Relationship To Similar Equipment:
6625-01-034-6118