Part Number
DEMIL
Shelf Life
UOM
NIIN
Part Information
Output short circuit protected; dc input internal diode and fuse protects against reversed polarity; ac input fused; low voltage sensor, control circuit senses voltage level of mbu batteries, shuts mfs down to prevent complete discharge of batteries
NSN
National Stock Number:
TXT
Description:
Power Supply
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
Ncs mps power supply assembly
MRC:
The input value/s/,or range of values,for which the item is rated.APNX
Input Voltage Rating:
120.0 ac volts 3rd alternate operating power rqmt
MRC:
The input value/s/,or range of values,for which the item is rated.APNX
Input Voltage Rating:
22.5 dc volts 5th alternate operating power rqmt and 32.0 dc volts 5th alternate operating power rqmt
MRC:
The input value/s/,or range of values,for which the item is rated.APNX
Input Voltage Rating:
220.0 ac volts 2nd alternate operating power rqmt
MRC:
The input value/s/,or range of values,for which the item is rated.APNX
Input Voltage Rating:
240.0 ac volts 1st alternate operating power rqmt
MRC:
The input value/s/,or range of values,for which the item is rated.APNX
Input Voltage Rating:
110.0 ac volts 4th alternate operating power rqmt
MRC:
The output value/s/,or range of values,for which the item is rated.APPA
Output Voltage Rating:
20.5 dc volts single power output
MRC:
The number of complete cyclic changes,per unit of time,for which the input is rated.APTQ
Input Frequency Rating:
47.0 hertz 1st alternate operating power rqmt and 400.0 hertz 1st alternate operating power rqmt
MRC:
The number of complete cyclic changes,per unit of time,for which the input is rated.APTQ
Input Frequency Rating:
47.0 hertz 2nd alternate operating power rqmt and 400.0 hertz 2nd alternate operating power rqmt
MRC:
The number of complete cyclic changes,per unit of time,for which the input is rated.APTQ
Input Frequency Rating:
47.0 hertz 3rd alternate operating power rqmt and 400.0 hertz 3rd alternate operating power rqmt
MRC:
The number of complete cyclic changes,per unit of time,for which the input is rated.APTQ
Input Frequency Rating:
47.0 hertz 4th alternate operating power rqmt and 400.0 hertz 4th alternate operating power rqmt
MRC:
The ambient temperature range at which the item is designed to operate.AYNH
Operating Ambient Tempurature Range:
-25.0/+50.0 degrees celsius