Part Number 8101

Radio Frequency Transformer

Pricing & Availability

Submit this form for current pricing and availability of this NSN.
Part / NSN:
Qty:
Your Email:
Phone:
Ref. / PO #:
Company:
Your Name:

We do not share or sell your information to anyone.
Privacy | Terms

All major credit cards accepted as well as gov. p-cards
Part Number
DEMIL
Shelf Life
UOM
NIIN
Part:
8101
Demil:
No
Shelf Life:
UOM:
NIIN:
010067859

Part Information
Primary shield is brought out to primary terminal; secondary shield is brought out to secondary terminal

NSN
National Stock Number:
5950-01-006-7859 5950010067859
TXT
Description:
Radio Frequency Transformer
INC
INC
Item Name Code:
00777
MRC:
An indication that the level of probability that an item will operate without failure,at a specified rated capability,at a specified temperature,and for a specified period of time,has been established by testing random samples of production lot.AARG
Reliability Indicator:
Not established
MRC:
The value(s) of inductance inherent in the item.ACYV
Inductance Rating:
16.00 millihenries single component all primary
MRC:
The value(s) of inductance inherent in the item.ACYV
Inductance Rating:
16.00 millihenries single component all secondary
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
4.8 megahertz single component
MRC:
Indicates the type of support on which the coil is wound.ACZP
Coil Form Type:
Solid single component
MRC:
The means by which a protective metal screen,plate,or inclosure is placed around or between the windings of an item to prevent electrostatic or magnetic coupling.ACZX
Winding Shielding Method:
Primary and secondary shielded and brought out to terminal single component and core grounded and brought out to terminal single component
MRC:
A measurement of the longest dimension of the body,in distinction from width.ADAQ
Body Length:
Between 1.720 inches and 1.780 inches
MRC:
A measurement taken at right angles to the length of the body,in distinction from thickness.ADAT
Body Width:
Between 1.720 inches and 1.780 inches
MRC:
A measurement from the bottom to the top of the body,in distinction from depth.ADAU
Body Height:
Between 2.630 inches and 2.870 inches
MRC:
The distance between mounting facility centers.AEJN
Distance Between Mounting Facility Centers:
1.480 inches single mounting facility single center group and 1.520 inches single mounting facility single center group
MRC:
Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
Inclosure Type:
Fully enclosed
MRC:
The number of mounting facilities provided.AKPV
Mounting Facility Quantity:
2 single group
MRC:
The means of attaching the item.AXGY
Mounting Method:
Threaded stud single group
MRC:
The means by which the rating is determined.BKPL
Rating Method:
Electrical single component all secondary
MRC:
The means by which the rating is determined.BKPL
Rating Method:
Electrical single component all primary
MRC:
The purpose and the total number of individual (not electrically connected) windings designed to perform in a transformer.BPLC
Winding Function And Quantity:
2 primary single component and 2 secondary single component
MRC:
Those features,not otherwise specified,which may be required for proper functioning of the item.CBBL
Features Provided:
Color coded lead
MRC:
A designation that is used for the purpose of general identification of the thread.CQJX
Thread Size:
0.138 inches single group
MRC:
The size of the conductor which forms the winding on the item.CQPZ
Winding Conductor Size:
0.01264 inches american wire gage single component all primary
MRC:
The size of the conductor which forms the winding on the item.CQPZ
Winding Conductor Size:
0.01264 inches american wire gage single component all secondary
MRC:
A designation distinguishing one group of thread diameter-pitch combinations from another by the number of threads per measurement scale for a specific diameter.THSD
Thread Series Designator:
Unc single group
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
9 wire lead

Similar Radio Frequency Transformers

« Coils and Transformers Catalog
Compare Now »
Clear | Hide