Part Number
DEMIL
Shelf Life
UOM
NIIN
NSN
National Stock Number:
TXT
Description:
Meter Movement Relay
MRC:
The number of terminals for providing electrical connection to the item.AARA
Terminal Quantity:
5
MRC:
Indicates the type of terminals for providing electrical connection to the item.AARB
Terminal Type:
Solder lug
MRC:
The element,compound,or mixture of which the case is fabricated,excluding any surface treatment.ADTV
Case Material:
Plastic
MRC:
The environmental elements or conditions that an item is designed or protected to resist or withstand satisfactorily.ADZC
Environmental Protection:
Dustproof
MRC:
The pattern or arrangement that describes the mounting configuration of the item.ALGC
Mounting Configuration:
Four 0.145 in. Diameter mtg holes on 1.06 in. By 1.93 in. Mtg centers
MRC:
The value(s) of potential for which the item is rated.AMSE
Voltage Rating:
120.0 volts
MRC:
The designation that identifies the schematic diagram of the electrical configuration of the main contacts including the number of poles or forms.APDZ
Main Contact Arrangement:
1 pole, double throw, one position momentary
MRC:
Indicates the type of current used by the main contact/s/.APEB
Main Contact Current Type:
Dc
MRC:
The current rating of the main contact/s/.APEC
Main Contact Current Rating:
50.0 milliamperes
MRC:
Indicates the type of current used in the meter movement.APGN
Meter Movement Current Type:
Dc
MRC:
The amount of voltage required to operate the meter movement,expressed in volts.APGP
Meter Movement Voltage In Volts:
12.000
MRC:
An indication of the minimum and maximum amount of current used in the meter movement.APGR
Meter Movement Current Range:
-2.0/+2.0 microamperes
MRC:
The cycles per second /hertz/ of current of the meter movement.APML
Meter Movement Frequency Rating:
60.0 hertz
MRC:
Indicates the type of mount utilized to support the meter.APMR
Meter Mounting Type:
Surface
MRC:
An indication of the specific condition that causes the contacts to close.APMT
Contact Closing Condition:
Increase value
MRC:
An indication of whether or not the reset facilities are provided.APNR
Reset Facility Feature:
Provided
MRC:
Indicates the type of lock in device provided.APNS
Lock In Device Type:
Permanent magnet
MRC:
The means by which the item is released.APNT
Release Method:
Electromagnetic
MRC:
A measurement between specified points of the meter to the panel, in distinction from height.APSS
Err Default:
Err default
MRC:
A measurement between specified points of the meter to the panel, in distinction from height.APSS
Meter Depth To Panel:
1.343 inches
MRC:
A measurement of the longest dimension of the meter body,in distinction from width.APTG
Err Default:
Err default
MRC:
A measurement of the longest dimension of the meter body,in distinction from width.APTG
Meter Body Length:
1.546 inches
MRC:
A measurement taken at right angles to the length of the meter body, in distinction from thickness.APTH
Err Default:
Err default
MRC:
A measurement taken at right angles to the length of the meter body, in distinction from thickness.APTH
Meter Body Width:
2.156 inches