Part Number
DEMIL
Shelf Life
UOM
NIIN
Part Information
Wires 1 and 2 are twisted together
NSN
National Stock Number:
TXT
Description:
Radio Frequency Transformer
MRC:
An indication that the level of probability that an item will operate without failure,at a specified rated capability,at a specified temperature,and for a specified period of time,has been established by testing random samples of production lot.AARG
Reliability Indicator:
Not established
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
6.750 inches
MRC:
The number of turns of conductive material forming the winding.ABHY
Turn Quantity:
4 single component 1st winding
MRC:
The number of turns of conductive material forming the winding.ABHY
Turn Quantity:
6 single component 2nd winding
MRC:
The number of turns of conductive material forming the winding.ABHY
Turn Quantity:
6 single component 3rd winding
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
4.570 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
3.220 inches
MRC:
The length of a straight line which passes through the center of a mounting hole,and terminates at the circumference.ABTB
Mounting Hole Diameter:
0.166 inches single group
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
400.0 hertz single component
MRC:
The means by which a protective metal screen,plate,or inclosure is placed around or between the windings of an item to prevent electrostatic or magnetic coupling.ACZX
Winding Shielding Method:
Internal shield grounded to inclosure single component
MRC:
The maximum temperature at which the item is rated to operate for an extended period of time.AEHZ
Maximum Operating Temp:
170.0 degrees celsius
MRC:
Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
Inclosure Type:
Open
MRC:
The number of mounting facilities provided.AKPV
Mounting Facility Quantity:
6 single group
MRC:
The means of attaching the item.AXGY
Mounting Method:
Unthreaded hole single group
MRC:
The means by which the rating is determined.BKPL
Rating Method:
Winding turns single component all winding
MRC:
The size of the conductor which forms the winding on the item.CQPZ
Winding Conductor Size:
0.01264 inches american wire gage single component all winding
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
6 wire lead