Part Number
DEMIL
Shelf Life
UOM
NIIN
NSN
National Stock Number:
TXT
Description:
Rotary Switch
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
6.312 inches
First Flat Length:
0.500 inches single actuator
Flat Height:
0.312 inches single actuator
MRC:
The length of a straight line which passes through the center of a shaft,and terminates at the circumference.ABWV
Shaft Diameter:
0.375 inches single actuator
MRC:
A measurement of the longest dimension of the shaft,in distinction from width.ABXF
Shaft Length:
0.687 inches single actuator
MRC:
A measurement of the longest straight line across a circular cross-sectional plane.ADAV
Overall Diameter:
3.781 inches
MRC:
The number of individual sections included in the item.AFBH
Individual Section Quantity:
12
MRC:
The identifying code of the orginator that controls or manufacturers the knob.AFCQ
Knob Manufacturer Code:
04009
MRC:
The longest distance between mounting centers parallel to the horizontal plane.AFDS
Longest Horizontal Distance Between Mounting Centers:
3.218 inches single mounting facility
MRC:
The longest distance between mounting centers parallel to the vertical plane.AFDV
Longest Vertical Distance Between Mounting Centers:
3.218 inches single mounting facility
MRC:
The general configuration of the contacts of a switch that describes its basic switching structure.AJZE
Switch Contact Basic Design:
Nonpile-up symmetrical
MRC:
The number of poles included in the item.AKPX
Pole Quantity:
1 each section front
MRC:
The number of positions to which the item may be actuated to energize electrical circuits.AKPY
Throw Quantity:
4 each section front
MRC:
The means of attaching the item.AXGY
Mounting Method:
Threaded bushing single mounting facility
MRC:
Those features,not otherwise specified,which may be required for proper functioning of the item.CBBL
Features Provided:
Actuator knob
MRC:
The number of threads on the item per linear inch measured on a line parallel to the thread axis.CMLP
Thready Qty Per Inch (tpi):
20 single mounting facility
MRC:
A designation that is used for the purpose of general identification of the thread.CQJX
Thread Size:
0.250 inches single mounting facility
MRC:
The voltage for which the contacts are rated,expressed in volts.CQMK
Contact Voltage Rating In Volts:
125.0 lowest ac voltage rating at sea level
MRC:
The voltage for which the contacts are rated,expressed in volts.CQMK
Contact Voltage Rating In Volts:
500.0 highest ac voltage rating at sea level
MRC:
The general configuration and relative position of the facilities provided for mounting the item.CQYJ
Mounting Facility Pattern:
Four position rectangular single mounting facility
MRC:
The number of positions to which the switch actuator may be indexed.CRJH
Switch Actuator Indexing Position Quantity:
4 single actuator
MRC:
Indicates the type of shaft included on the item.CRSJ
Shaft Type:
Round, flatted, threaded hole single actuator
MRC:
Indicates the type of terminal for providing electrical connection to the item.CSCF
Terminal Type:
Tab w/screw
MRC:
An indication of the switching action by the contacts of the item.CSHW
Contact Switching Action:
Makes before breaks, breaks before makes each section front
MRC:
The increments of angular rotation that the switch actuator moves between adjacent index positions.CSLC
Switch Actuator Positioning Increment:
90.0 degrees single actuator
MRC:
The amount of current that the contacts are rated to make or break with a specified load.CTHF
Contact Load Current Rating:
30.0 amperes resistive load lowest ac voltage rating at sea level
MRC:
The amount of current that the contacts are rated to make or break with a specified load.CTHF
Contact Load Current Rating:
10.0 amperes resistive load highest ac voltage rating at sea level
MRC:
A designation distinguishing one group of thread diameter-pitch combinations from another by the number of threads per measurement scale for a specific diameter.THSD
Thread Series Designator:
Unc single mounting facility