Part Number
DEMIL
Shelf Life
UOM
NIIN
Part Information
temperature 3000 deg. F, continuous 300 to 2500 degrees f.
NSN
National Stock Number:
TXT
Description:
Laboratory Muffle Furnace
MRC:
Indicates the type of current whether alternating,direct,or both.ACDC
Current Type:
Ac
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
60.0 hertz
MRC:
An inside measurement taken at right angles to the length of an item,in distinction from thickness.ADJT
Inside Width:
6.0000 inches
MRC:
An outside measurement taken at right angles to the length of an item,in distinction from thickness.ADJV
Outside Width:
31.750 inches
MRC:
An inside measurement between specified points of an item,in distinction from height.AFEF
Inside Depth:
12.000 inches
MRC:
An inside measurement from the bottom to the top of an item,in distinction from depth.AFMQ
Inside Height:
4.750 inches
MRC:
An outside measurement from the bottom to the top of an item,in distinction from depth.AFMW
Outside Height:
26.000 inches
MRC:
The name and number of parts supplied with the item which may be required for application.AKYD
Accessory Components And Quantity:
10 silicon carbide heating elements, pyrometer temperature controller
MRC:
The value(s) of potential for which the item is rated.AMSE
Voltage Rating:
230.0 volts
MRC:
The amount of electrical energy that can be dissipated.ANPT
Power Rating:
8500.0 watts
MRC:
Indicates the type of control.AQZF
Control Type:
Temperature control dial
MRC:
The heat source for which the item is designed.AZZH
Heat Source For Which Designed:
Integral
MRC:
An outside measurement between specified points on an item,in distinction from height.BCXB
Outside Depth:
28.250 inches
MRC:
The means by which the item is heated.BDWT
Heating Method:
Electrical
MRC:
An indication of whether or not the item is provided with a water jacket.BGXH
Water Jacket:
Not provided
MRC:
An indication of whether or not an insulated cabinet is provided.BLST
Insulated Cabinet:
Provided
MRC:
An indication of whether or not cooling coils for below room temperature use are included.BNDW
Cooling Coils For Below Room Tempurature Use:
Not included
MRC:
The element,compound,or mixture of which the cabinet outer wall is fabricated,excluding any surface treatment.BQMH
Cabinet Outer Wall Material:
Steel
MRC:
The element,compound,or mixture of which the cabinet inner wall is fabricated,excluding any surface treatment.BQMJ
Cabinet Inner Wall Material:
Steel
MRC:
Indicates the type of mount utilized to support the cabinet.BQML
Cabinet Mounting Type:
Stand
MRC:
The number of outer doors included.BQMN
Outer Door Quantity:
1
MRC:
The element,compound,or mixture of which the outer door is fabricated,excluding any surface treatment.BQMP
Outer Door Material:
Steel
MRC:
The number of alternating current phases.FAAZ
Phase:
Single