Part Number
DEMIL
Shelf Life
UOM
NIIN
Part Information
Components for this assembly are power supply/upsr-200 (6130-01-315-2427), battery assembly/lb60v-25, 5 batteries/0829-0020, cable interconnect/a80867
NSN
National Stock Number:
TXT
Description:
Power Supply
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
14.500 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
10.250 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
19.000 inches
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
Anti-intrusion alarm system an/gss-3 (v)
MRC:
The relationship of the electrical power source to the item.AKWC
Electrical Power Source Relationship:
Operating
MRC:
The input value/s/,or range of values,for which the item is rated.APNX
Input Voltage Rating:
108.0 ac pounds per hour dry 2nd alternate operating power rqmt and 132.0 ac pounds per hour with retaining chain 2nd alternate operating power rqmt
MRC:
The input value/s/,or range of values,for which the item is rated.APNX
Input Voltage Rating:
216.0 ac pounds per hour dry 1st alternate operating power rqmt and 264.0 ac pounds per hour with retaining chain 1st alternate operating power rqmt
MRC:
The output value/s/,or range of values,for which the item is rated.APPA
Output Voltage Rating:
108.0 ac volts 2nd power output and 132.0 ac volts 2nd power output
MRC:
The output value/s/,or range of values,for which the item is rated.APPA
Output Voltage Rating:
216.0 ac volts 1st power output and 264.0 ac volts 1st power output
MRC:
The number of complete cyclic changes,per unit of time,for which the input is rated.APTQ
Input Frequency Rating:
50.0 hertz 1st alternate operating power rqmt and 60.0 hertz 1st alternate operating power rqmt
MRC:
The number of complete cyclic changes,per unit of time,for which the input is rated.APTQ
Input Frequency Rating:
50.0 hertz 2nd alternate operating power rqmt and 60.0 hertz 2nd alternate operating power rqmt
MRC:
The number of complete cyclic changes,per unit of time,for which the output is rated.APTS
Output Frequency Rating:
59.0 hertz 2nd power output and 61.0 hertz 2nd power output
MRC:
The number of complete cyclic changes,per unit of time,for which the output is rated.APTS
Output Frequency Rating:
59.0 hertz 1st power output and 61.0 hertz 1st power output
MRC:
The rated output power that an item can safely consume or provide,measured in watts.BGQR
Output Wattage Rating:
150.0 watts single power output
MRC:
The number of output alternating current phases.CWGN
Output Phase:
Single single power output