Part Number 8761B001

Radio Frequency Transmiss Switch
Description

Thread class 2b mounting facility hole radio frequency transmiss switch nsn 5985000096482.

Pricing & Availability

Submit this form for current pricing and availability of this NSN.
Part / NSN:
Qty:
Your Email:
Phone:
Ref. / PO #:
Company:
Your Name:

We do not share or sell your information to anyone.
Privacy | Terms

All major credit cards accepted as well as gov. p-cards
Part Number
DEMIL
Shelf Life
UOM
NIIN
Part:
8761b001
Demil:
No
Shelf Life:
UOM:
NIIN:
000096482
NSN
National Stock Number:
5985-00-009-6482 5985000096482
TXT
Description:
Radio Frequency Transmiss Switch
INC
INC
Item Name Code:
05298
MRC:
A numeric-alpha designator indicating the pitch diameter tolerance and an external or internal thread.AAJD
Thread Class:
2b mounting facility hole
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the body.AAQL
Body Style:
Rectangular
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
2.547 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
2.015 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
1.455 inches
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
0.0 gigahertz 1st frequency crosstalk reference and 12.4 gigahertz 1st frequency crosstalk reference
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
0.0 gigahertz 1st frequency insertion loss reference and 12.4 gigahertz 1st frequency insertion loss reference
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
12.4 gigahertz 2nd frequency insertion loss reference and 18.0 gigahertz 2nd frequency insertion loss reference
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
12.4 gigahertz 2nd frequency crosstalk reference and 18.0 gigahertz 2nd frequency crosstalk reference
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
0.0 gigahertz single frequency operating and 18.0 gigahertz single frequency operating
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
0.0 gigahertz single frequency rf power handling and 18.0 gigahertz single frequency rf power handling
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
0.0 gigahertz single frequency voltage standing wave ratio and 18.0 gigahertz single frequency voltage standing wave ratio
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
0.0 gigahertz and 12.4 gigahertz 1st frequency crosstalk reference
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
0.0 gigahertz and 12.4 gigahertz 1st frequency insertion loss reference
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
0.0 gigahertz and 18.0 gigahertz single frequency operating
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
0.0 gigahertz and 18.0 gigahertz single frequency rf power handling
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
0.0 gigahertz and 18.0 gigahertz single frequency voltage standing wave ratio
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
12.4 gigahertz and 18.0 gigahertz 2nd frequency crosstalk reference
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
12.4 gigahertz and 18.0 gigahertz 2nd frequency insertion loss reference
MRC:
Indicates the type of switch included in the item.AEEA
Switch Type:
Transfer
MRC:
The distance between mounting facility centers.AEJN
Distance Between Mounting Facility Centers:
1.150 inches single mounting facility pattern
MRC:
The ratio of the maximum to the minimum amplitude of pressure /voltage/ measured along the path of the waves.AHTW
Voltage Standing Wave Ratio:
1.25 single
MRC:
The difference in the amount of energy available before and after the insertion of an apparatus in a transmission system,expressed in decibels.AHTX
Insertion Loss In Decibels:
0.40 1st
MRC:
The difference in the amount of energy available before and after the insertion of an apparatus in a transmission system,expressed in decibels.AHTX
Insertion Loss In Decibels:
0.80 2nd
MRC:
A letter or group of letters used to designate the particular coaxial connector series.AHUC
Coaxial Connector Series Designation:
N and n
MRC:
The design of the connector end.AHUD
Connector End Design:
Male and female
MRC:
The amount of radio frequency power handling capability that can be dissipated safely by an item.AKNF
Rf Power Handling Capability:
2.0 watts average 1st
MRC:
The amount of radio frequency power handling capability that can be dissipated safely by an item.AKNF
Rf Power Handling Capability:
300.0 watts peak 2nd
MRC:
The minimum amount of isolation the item offers against interference from adjacent channel operation,expressed in decibels.AKNV
Minimum Crosstalk Rating In Decibels:
50.0 1st
MRC:
The minimum amount of isolation the item offers against interference from adjacent channel operation,expressed in decibels.AKNV
Minimum Crosstalk Rating In Decibels:
45.0 2nd
MRC:
The means provided for switching the actuator from one position to another.AKPC
Actuator Operating Method:
Relay
MRC:
The actuator current type and amount of electron flow at which the item is designed to operate,expressed in amperes.AKPE
Actuator Current Type And Rating In Amps:
0.5 dc
MRC:
The value/s/,or range of values,of potential for which the item is rated,expressed in volts.AKPJ
Actuator Voltage In Volts:
Between 24.0 and 30.0
MRC:
An indication of whether the lobe of the rotating cam is designed to actuate /make/ a switch before or after the preceding switch deactuates /breaks/.AKPN
Switch Operation Sequence:
Makes before breaks
MRC:
The time required for switching between any two adjacent positions.AKPP
Switching Time:
40.0 milliseconds
MRC:
The operation of the switch mechanism when the switch return actuator power is removed.AKPQ
Switch Return Mechanism Type:
Latching
MRC:
The number of coupling positions provided.AKRC
Coupling Position Quantity:
3
MRC:
Indicates the type and number of facilities by which the item is mounted.AXHR
Mounting Facility Type And Quantity:
2 threaded hole
MRC:
A designation that is used for the purpose of general identification of the thread.CQJX
Thread Size:
0.138 inches mounting facility hole
MRC:
The general configuration and relative position of the facilities provided for mounting the item.CQYJ
Mounting Facility Pattern:
Two position in-line single mounting facility pattern
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Metal body
MRC:
A designation distinguishing one group of thread diameter-pitch combinations from another by the number of threads per measurement scale for a specific diameter.THSD
Thread Series Designator:
Unc mounting facility hole
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
1 plug, coaxial and 2 receptacle, coaxial and 2 turret

Similar Radio Frequency Transmiss Switches

« Antennas, Waveguides and Related Equipment Catalog
Compare Now »
Clear | Hide