Part Number
DEMIL
Shelf Life
UOM
NIIN
NSN
National Stock Number:
TXT
Description:
Unitized Semiconductor Devices
MRC:
The element,compound,or mixture of which the inclosure is fabricated,excluding any surface treatment.ABBH
Inclosure Material:
Plastic
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
0.240 inches
MRC:
A measurement of the longest dimension of a terminal,in distinction from width.ABJT
Terminal Length:
0.200 inches
MRC:
A measurement of the longest straight line across a circular cross-sectional plane.ADAV
Overall Diameter:
0.500 inches
MRC:
The name and number of components included.ASKA
Component Name And Quantity:
2 transistor
MRC:
The means of attaching the item.AXGY
Mounting Method:
Terminal
MRC:
The chemical compound or mechanical mixture properties of which the semiconductor is fabricated.CTMZ
Semiconductor Material:
Silicon all transistor
MRC:
The value of the voltage that may be applied,expressed in volts,and the symbol used to identify the specific electrical characteristic.CTQN
Voltage Rating In Volts Per Characteristic:
45.0 breakdown voltage, collector-to-base, emitter open all transistor and 5.0 breakdown voltage, emitter-to-base, collector open all transistor and 45.0 breakdown voltage, collector-to-emitter, base open all transistor
MRC:
The level of electrical flow and the symbol used to identify the specific electrical characteristic.CTQX
Current Rating Per Characteristic:
25.00 milliamperes all primaries all transistor
MRC:
The amount of electrical power that can be dissipated and the specific electrical characteristic.CTRD
Power Rating Per Characteristic:
640.0 milliwatts any acceptable preset all transistor
MRC:
The maximum temperature at which the item is designed to operate at each measurement point.CTSG
Maximum Operating Tempurature Per Measurement Point:
85.0 degrees celsius ambient air
MRC:
The specification,standard,drawing,or similar instrument that specifies environmental and performance requirements or test conditions under which an item is tested and establishes acceptable limits within which the item must conform identified by an alphabetic and/or numeric reference number. includes the commercial and government entity (cage) code of the entity controlling the instrument.TEST
Test Data Document:
98750-8949408 drawing (this is the basic governing drawing, such as a contractor drawing, original equipment manufacturer drawing, etc.; excludes any specification, standard or other document that may be referenced in a basic governing drawing)
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
8 uninsulated wire lead