Part Number 898074-1-1

Fluid Pressure Regulating Valve

Pricing & Availability

Submit this form for current pricing and availability of this NSN.
Part / NSN:
Qty:
Your Email:
Phone:
Ref. / PO #:
Company:
Your Name:

We do not share or sell your information to anyone.
Privacy | Terms

All major credit cards accepted as well as gov. p-cards
Part Number
DEMIL
Shelf Life
UOM
NIIN
Part:
898074-1-1
Demil:
Yes - DEMIL/MLI
Shelf Life:
UOM:
NIIN:
001105353
NSN
National Stock Number:
4820-00-110-5353 4820001105353
TXT
Description:
Fluid Pressure Regulating Valve
INC
INC
Item Name Code:
27565
INC
COM
Compliance:
MRC:
The basic material of which the body is fabricated.AAFZ
Body Material:
Aluminum alloy
MRC:
None.AAHF
First End Flange Outside Diameter:
3.117 inches
MRC:
None.AAHV
Second End Flange Outside Diameter:
2.117 inches
MRC:
Consists of plating,dip,and/or coating that cannot be wiped off. plating and/or coating is any chemical and/or metallic additive,electrochemical,or mild mechanical process which protects the outside surface.AAJP
Outside Surface Treatment:
Nickel
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the body.AAQL
Body Style:
Tee
MRC:
The element, compound,or mixture of which the stem is fabricated,excluding any surface treatment.ABEP
Stem Material:
Steel, qq-s-763, class 316
MRC:
The type of service with which the item is designed to be used.ACKL
Media For Which Designed:
Air
MRC:
A narrative description of the type of end connection.ACKM
First End Connection Type:
Plain face flange
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the end.ACKN
First End Style Designator:
Plain
MRC:
The style designation indicating the configuration that most nearly corresponds to the shape of the end flange.ACKT
First End Flange Shape Style:
Round
MRC:
A measurement of the smallest dimension of the first end flange, in distinction from length or width.ACKU
First End Flange Thickness:
0.206 inches
MRC:
Indicates whether or not the second end is identical to the first end.ACLR
Second End Relationship With First End:
Not identical
MRC:
A narrative description of the type of end connection.ACLS
Second End Connection Type:
Plain face flange
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the end.ACLT
Second End Style Designator:
Plain
MRC:
The style designation indicating the configuration that most nearly corresponds to the shape of the end flange.ACLY
Second End Flange Shape Style:
Round
MRC:
A measurement of the smallest dimension of the second end flange, in distinction from length or width.ACLZ
Second End Flange Thickness:
0.206 inches
MRC:
Indicates whether or not the third end is identical with first or second end.ACMX
Third End Relationship With Preceding Ends:
Not identical with first or second end
MRC:
A narrative description of the type of end connection.ACMY
Third End Connection Type:
Threaded internal boss
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the end.ACMZ
Third End Style Designator:
Gasket seal
MRC:
Designates the thread diameter,series/type,and number of threads per specific measurement scale.ACNX
Third End Thread Size And Series/type Designator:
7/16-20 unjf
MRC:
A numeric-alpha designator indicating the pitch diameter tolerance and an external or internal thread.ACNY
Third End Thread Class:
3b
MRC:
The direction of the thread when viewed axially. a right-hand thread winds in a clockwise direction while a left-hand thread winds in a counterclockwise direction.ACNZ
Third End Thread Direction:
Right-hand
MRC:
The element,compound,or mixture of which the seating surfaces are fabricated.ACSH
Seat Material:
Steel, qq-s-763, class 316
MRC:
None.ADQM
First Connection Face To Centerline Distance:
1.280 inches
MRC:
None.ADQN
Second Connection Face To Centerline Distance:
2.900 inches
MRC:
The center to center distance.ADQR
Center To Center Distance:
3.240 inches
MRC:
The part that controls the flow through the item.ADQU
Flow Control Device:
Diaphragm
MRC:
The number of end connections included in the item.ADQZ
End Connection Quantity:
3
MRC:
The means other than the end connection/s/ by which the item may be mounted.ADZJ
Mounting Facility:
Bracket
MRC:
The minimum to maximum limits of outlet pressure of the item.AEVA
Outlet Pressure Range:
+32.0/+38.0 pounds per square inch
MRC:
Indicates the basic design type used for regulating the item.AEVN
Regulation Type:
Automatic single stage
MRC:
The seat design of the valve stem.AEVQ
Valve Stem Design:
Single seat
MRC:
The means of providing resistance to the media passing through a valve,whereby the valve is actuated to regulate the flow.AEVR
Valve Loading Method:
Spring
MRC:
The set /nonadjustable/ pressure of the media on the outlet side.AEWA
Outlet Pressure Setting:
35.0 pounds per square inch
MRC:
An indication of whether or not a filter is included.AEWF
Filter:
Not included
MRC:
A value which expresses the degree of heat or cold as applied to the operation,or limitation of operation,of an item.AZKQ
Tempurature Rating:
Between -65.0 degrees fahrenheit and 238.0 degrees fahrenheit

Similar Fluid Pressure Regulating Valves

« Nonpowered Valves Catalog
Compare Now »
Clear | Hide