Part Number 8BC375300-KL

Band Pass Filter

Pricing & Availability

Submit this form for current pricing and availability of this NSN.
Part / NSN:
Qty:
Your Email:
Phone:
Ref. / PO #:
Company:
Your Name:

We do not share or sell your information to anyone.
Privacy | Terms

All major credit cards accepted as well as gov. p-cards
Part Number
DEMIL
Shelf Life
UOM
NIIN
Part:
8bc375300-kl
Demil:
No
Shelf Life:
UOM:
NIIN:
010407531
NSN
National Stock Number:
5915-01-040-7531 5915010407531
TXT
Description:
Band Pass Filter
INC
INC
Item Name Code:
00209
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
Between 4.950 inches and 5.180 inches
MRC:
The length of a straight line which passes through the center of the body,and terminates at the outside circumference.ADAR
Body Outside Diameter:
0.500 inches
MRC:
The minimum and maximum limits of temperature at which the item is rated for operation.AFGA
Operating Tempurature Range:
+10.0/+85.0 degrees celsius
MRC:
The frequency at which the insertion loss is measured per function,and to which all related attenuation loss measurements are referred.AHAJ
Reference Frequency Per Function:
375.0 megahertz blank
MRC:
The total opposition per function with load (resistive and reactive) presented by the device to the source (asa c42.65,paragraph 65.08.399).AHAU
Input Impedance Per Function W/load:
50.0 ohms blank
MRC:
The total opposition per function with source across input (resistive and reactive) presented by the device to the load (asa c42.65,paragraph 65.08.402).AHAV
Output Impedance Per Function W/source Across Input:
50.0 ohms blank
MRC:
The identifying numeric code of the originator that controls or manufactures the input terminal.AHBN
Input Terminal Manufacturer Code:
07397
MRC:
The specification,standard,or manufacturers identification number or symbol used to identify the input terminal.AHBP
Input Terminal Identification:
Sma
MRC:
The identifying numeric code of the originator that controls or manufactures the output terminal.AHBS
Output Terminal Manufacturer Code:
07397
MRC:
The specification,standard,or manufacturers identification number or symbol used to identify the output terminal.AHBT
Output Terminal Identification:
Sma
MRC:
The ratio of the maximum to the minimum voltage of the standing wave per function. the larger relative portion is given,the lower value having an implied /not given/ value of one /unity/.AHBZ
Voltage Standing Wave Ratio Per Function:
1.5 blank
MRC:
Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
Inclosure Type:
Encased
MRC:
Indicates the type and number of facilities by which the item is mounted.AXHR
Mounting Facility Type And Quantity:
2 connector
MRC:
The ratio per function of the power delivered to the load before insertion of the filter to the power delivered to the load after insertion of the filter,expressed in decibels.CQDR
Insertion Loss At Reference Frequency Per Function In Decibels:
0.5 blank
MRC:
Indicates the functional type and number of terminals providing electrical connection to the item.CQDW
Functional Terminal Type And Quantity:
1 connector, receptacle input 1st function
MRC:
Indicates the functional type and number of terminals providing electrical connection to the item.CQDW
Functional Terminal Type And Quantity:
1 connector, receptacle output 2nd function
MRC:
The specified frequencies,per function,at which losses in signal strength are,by design or measurement,established in a filter circuit.CQFC
Specified Frequencies Of Discrimination Per Function:
125.00 megahertz blank and 235.00 megahertz blank and 515.00 megahertz blank and 680.00 megahertz blank
MRC:
The difference,per function,between the limiting frequencies within which performance,in respect to some characteristic,falls within specified limits.CRBB
Frequency Band Width Per Function:
235.00 megahertz blank and 515.00 megahertz blank
MRC:
The algebraic difference between the insertion loss at a specified frequency and the insertion loss at the reference frequency per function,expressed in decibels.CRBC
Discrimination At Specificationified Frequencies Per Function In Decibels:
20.0 blank and 1.0 blank and 1.0 blank and 20.0 blank
MRC:
The minimum and maximum values of frequency,per function,between which the voltage standing wave ratio is specified.CRBN
Voltage Standing Wave Ratio Frequency Limits Per Function:
235.0 megahertz blank and 515.0 megahertz blank
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the item.STYL
Style Designator:
Round terminal/terminals on opposite surfaces
MRC:
The specification,standard,drawing,or similar instrument that specifies environmental and performance requirements or test conditions under which an item is tested and establishes acceptable limits within which the item must conform identified by an alphabetic and/or numeric reference number. includes the commercial and government entity (cage) code of the entity controlling the instrument.TEST
Test Data Document:
07397-32-808852 drawing (this is the basic governing drawing, such as a contractor drawing, original equipment manufacturer drawing, etc.; excludes any specification, standard or other document that may be referenced in a basic governing drawing)

Similar Band Pass Filters

« Filters and Networks Catalog
Compare Now »
Clear | Hide