Part Number 9131665

Distribution Box

Pricing & Availability

Submit this form for current pricing and availability of this NSN.
Part / NSN:
Qty:
Your Email:
Phone:
Ref. / PO #:
Company:
Your Name:

We do not share or sell your information to anyone.
Privacy | Terms

All major credit cards accepted as well as gov. p-cards
Part Number
DEMIL
Shelf Life
UOM
NIIN
Part:
9131665
Demil:
No
Shelf Life:
UOM:
NIIN:
011625949

Part Information
W/3 bus bars; red globe for indicator lights

NSN
National Stock Number:
6110-01-162-5949 6110011625949
TXT
Description:
Distribution Box
INC
INC
Item Name Code:
19735
MRC:
An overall measurement between specified points of an item,in distinction from height.ABFY
Overall Depth:
7.875 inches
MRC:
The distance between the center of one mounting facility and the center of the adjacent mounting facility parallel to the width.ABKR
Center To Center Distance Between Mounting Facilities Parallel To Width:
18.875 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
24.000 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
20.500 inches
MRC:
The name and number of those parts furnished with the item of supply that have not been specified elsewhere.ACSY
Furnished Items And Quantity:
1 cover and 2 indicator, light
MRC:
The length of a straight line which passes through the center of an unthreaded mounting hole,and terminates at the circumference.AEBV
Unthreaded Mounting Hole Diameter:
0.531 inches
MRC:
The distance between the center of one mounting facility and the center of the adjacent mounting facility parallel to the height.AEBW
Center To Center Distance Between Mounting Facilities Parallel To Height:
11.625 inches
MRC:
A designation of the standard mounting facility arrangement provided.AESL
Standard Mounting Pattern Designator:
4 point-rectangular
MRC:
The means of attaching the item.AXGY
Mounting Method:
Unthreaded hole
MRC:
The maximum current rating of the main line,expressed in amperes.BFYC
Main Line Maximum Current Rating In Amps:
250.0
MRC:
Indicates the type and number of circuit breakers provided.BGJL
Circuit Breaker Type And Quantity:
2 double pole
MRC:
The maximum electrical current which the circuit breaker will carry without interrupting the circuit,expressed in amperes.BGJM
Circuit Breaker Current Rating In Amps:
250.0
MRC:
Describes the capabilities,intended use,and/or purpose for which the item is provided.FTLD
Functional Description:
Manual bus transfer
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Steel
MRC:
The metallic,nonmetallic,and/or chemical properties with which the item is plated,dipped,and/or coated.the treatment is designed to protect the surface(s) and cannot be wiped off.SFTT
Surface Treatment:
Enamel
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the item.STYL
Style Designator:
Rectangular, surface mounting

Similar Distribution Boxs

« Electrical Control Equipment Catalog
Compare Now »
Clear | Hide