Part Number 92007A0082

Electrical Solenoid

Pricing & Availability

Submit this form for current pricing and availability of this NSN.
Part / NSN:
Qty:
Your Email:
Phone:
Ref. / PO #:
Company:
Your Name:

We do not share or sell your information to anyone.
Privacy | Terms

All major credit cards accepted as well as gov. p-cards
Part Number
DEMIL
Shelf Life
UOM
NIIN
Part:
92007a0082
Demil:
No
Shelf Life:
UOM:
NIIN:
014252254
NSN
National Stock Number:
5945-01-425-2254 5945014252254
TXT
Description:
Electrical Solenoid
INC
INC
Item Name Code:
00310
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the body.AAQL
Body Style:
Cylindrical
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
2.030 inches
MRC:
The distance between the center of one mounting facility and the center of the adjacent mounting facility parallel to the length.ABKQ
Center To Center Distance Between Mounting Facilities Parallel To Length:
1.922 inches
MRC:
A measurement of the longest straight line across a circular cross-sectional plane.ADAV
Overall Diameter:
1.510 inches
MRC:
The measurement of the distance that the actuator protrudes from the body.AFGK
Actuator Length:
0.450 inches
MRC:
The number of magnetic coils provided.APAF
Magnetic Coil Quantity:
1
MRC:
A measurement of the opposition to the flow of direct or alternating current.APCC
Electrical Resistance:
3.150 ohms
MRC:
Indicates the type of duty provided.APNP
Duty Type:
Intermittent
MRC:
The voltage rating at which the item is designed to operate,expressed in volts.ASXH
Voltage Rating In Volts:
20.0 dc and 30.0 dc
MRC:
Indicates the type and number of facilities by which the item is mounted.AXHR
Mounting Facility Type And Quantity:
2 unthreaded hole
MRC:
The movement of the actuator when force is applied.CNXT
Actuator Stroke Type:
Pull
MRC:
The amount of linear force delivered.CNXW
Linear Force Delivered:
13.00 pounds
MRC:
The maximum linear travel from the de-energized to the energized position.CNYD
Energizing Stroke Maximum Length:
0.192 inches

Similar Electrical Solenoids

« Relays and Solenoids Catalog
Compare Now »
Clear | Hide