Part Number
DEMIL
Shelf Life
UOM
NIIN
NSN
National Stock Number:
TXT
Description:
Band Pass Filter
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
Between 4.670 inches and 4.730 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
1.030 inches
MRC:
A measurement of the longest dimension of the body,in distinction from width.ADAQ
Body Length:
Between 3.970 inches and 4.030 inches
MRC:
A measurement taken at right angles to the length of the body,in distinction from thickness.ADAT
Body Width:
Between 1.470 inches and 1.530 inches
MRC:
The length of a straight line which passes through the center of an unthreaded mounting hole,and terminates at the circumference.AEBV
Unthreaded Mounting Hole Diameter:
0.025 inches
MRC:
The distance between centerlines of mounting facilities parallel to the length of the item.AEBY
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length:
Between 4.370 inches and 4.390 inches
MRC:
The low and high frequencies of vibratory motion and mechanical stresses between which the item is tested,or operated,without deleterious effect on its electrical or mechanical characteristics,expressed in hertz.AECR
Vibration Resistance Range In Hertz:
+100.0/+500.0
MRC:
The distance between centerlines of mounting facilities parallel to the width of the item.AEHA
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width:
Between 1.115 inches and 1.135 inches
MRC:
The minimum and maximum limits of temperature at which the item is rated for operation.AFGA
Operating Tempurature Range:
+0.0/+70.0 degrees celsius
MRC:
The frequency at which the insertion loss is measured per function,and to which all related attenuation loss measurements are referred.AHAJ
Reference Frequency Per Function:
255.0 megahertz blank
MRC:
The total opposition per function,presented by a source of energy to the input terminals of an item.AHAQ
Source Impedance Rating Per Function:
50.0 ohms blank
MRC:
The total opposition per function,presented by a load to the output terminals of an item.AHAS
Load Impedance Per Function:
50.0 ohms blank
MRC:
Indicates the type of principal circuitry per function interconnected within the item to produce the desired frequency versus attenuation characteristics.AHBL
Principal Circuitry Type Per Function:
Inductance-capacitance blank
MRC:
The identifying numeric code of the originator that controls or manufactures the input terminal.AHBN
Input Terminal Manufacturer Code:
49956
MRC:
The specification,standard,or manufacturers identification number or symbol used to identify the input terminal.AHBP
Input Terminal Identification:
Sma-receptacle
MRC:
The identifying numeric code of the originator that controls or manufactures the output terminal.AHBS
Output Terminal Manufacturer Code:
49956
MRC:
The specification,standard,or manufacturers identification number or symbol used to identify the output terminal.AHBT
Output Terminal Identification:
Sma-receptacle
MRC:
The ratio of the maximum to the minimum voltage of the standing wave per function. the larger relative portion is given,the lower value having an implied /not given/ value of one /unity/.AHBZ
Voltage Standing Wave Ratio Per Function:
1.5 blank
MRC:
The value of the average amount of electrical energy per function,which the item may pass or dissipate in continuous operation without degradation of physical or electrical characteristics.AHCH
Average Power Rating Per Function:
0.1 watts blank
MRC:
Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
Inclosure Type:
Encased
MRC:
Indicates the type and number of facilities by which the item is mounted.AXHR
Mounting Facility Type And Quantity:
4 unthreaded hole
MRC:
Those features,not otherwise specified,which may be required for proper functioning of the item.CBBL
Features Provided:
Moisture resistant
MRC:
The ratio per function of the power delivered to the load before insertion of the filter to the power delivered to the load after insertion of the filter,expressed in decibels.CQDR
Insertion Loss At Reference Frequency Per Function In Decibels:
0.8 blank
MRC:
The specified frequencies,per function,at which losses in signal strength are,by design or measurement,established in a filter circuit.CQFC
Specified Frequencies Of Discrimination Per Function:
170.00 megahertz blank and 230.00 megahertz blank and 280.00 megahertz blank and 340.00 megahertz blank
MRC:
The difference,per function,between the limiting frequencies within which performance,in respect to some characteristic,falls within specified limits.CRBB
Frequency Band Width Per Function:
230.00 megahertz blank and 280.00 megahertz blank
MRC:
The algebraic difference between the insertion loss at a specified frequency and the insertion loss at the reference frequency per function,expressed in decibels.CRBC
Discrimination At Specificationified Frequencies Per Function In Decibels:
40.0 blank and 1.0 blank and 1.0 blank and 40.0 blank
MRC:
The minimum and maximum values of frequency,per function,between which the voltage standing wave ratio is specified.CRBN
Voltage Standing Wave Ratio Frequency Limits Per Function:
230.0 megahertz blank and 280.0 megahertz blank
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the item.STYL
Style Designator:
Rectangular terminal/terminals on opposite surfaces
MRC:
The specification,standard,drawing,or similar instrument that specifies environmental and performance requirements or test conditions under which an item is tested and establishes acceptable limits within which the item must conform identified by an alphabetic and/or numeric reference number. includes the commercial and government entity (cage) code of the entity controlling the instrument.TEST
Test Data Document:
49956-929011 drawing (this is the basic governing drawing, such as a contractor drawing, original equipment manufacturer drawing, etc.; excludes any specification, standard or other document that may be referenced in a basic governing drawing)