Establishes the performance, design, development and test requirements for a closed loop liquid heat exchanger; unit is intended for cooling a load of 4.4 killowatts produced by electronic equipment mounted in a shipboard electronic warfare system; reservoir shall be pressurized to maintain a positive static pressure of 0.5 to 30 psi at highest point of total fluid system; indicatorsshall be used to read out coolant pressure, flow, flow rate, temperature and coolant filter condition; input power is single phase power derived from a 3 phase delta connected 60 hertz source with a voltage of 115 volts rms line to line; a filter cartridge of 60 micron shall be placed in series with the coolant flow; reservoir size shall be 9 gallons
Part Number | RNVC | RNAAC | DAC | CAGE |
---|---|---|---|---|
929166-1 | 2 | HD | 1 | 3B150 |
929166-1 | 9 | HD | 1 | 49956 |
Code | Definition |
---|---|
FN | Factory New. Parts manufactured by then OEM and includes manufacturer certification. |
NE | New. Parts manufactured by the OEM. May include manufacturer certification or company certification. |
NS | New Surplus. New material item purchased from excess inventory. |
OH | Overhauled. Product has been rebuilt and tested in accordance with the manufacturer's specifications by a repair shop (MRO). |
SV | Serviceable product. |
AR | As Removed. Product removed from aircraft or platform with no guarentee on the functionality of the part. |
RP | Repairable. Product can be repaired by a MRO and be given a FAA 8130 or EASA Form 1 certification. |