Line regulation=+ or - 0.05 percent for a 10 percent line change; load regulation=+ or - 0.05 percent for a 50 percent load change; output ripple=2v-15v units are 5.0mv pk-pk max., 20v-200v units are 0.02 percent pk-pk max.; transient response=50 sec. For a 50 percent load change; short circuit and overload protection=automatic current limit/foldback; remote sensing=open sense lead protection built-in; stability=+0.3 percent for 24 hr. Period after 1 hr. Warm-up; temp. Rating=0-50 deg. C. Full-rated, derated linearly to 40 percent at 70 deg. C.; temp. Coefficient=+ or - 0.03 percent/deg. C. Max.; efficiency=5v units are 45 percent, 12v and 15v units are 55 percent, 20v and 24v units are 60 percent
Part Number | RNVC | RNAAC | DAC | CAGE |
---|---|---|---|---|
9387301 | 2 | BF | 1 | 19200 |
HD12-6.8-A | 2 | ZZ | 5 | 54407 |
HD12-6.8 | 9 | BF | 5 | 54470 |
Code | Definition |
---|---|
FN | Factory New. Parts manufactured by then OEM and includes manufacturer certification. |
NE | New. Parts manufactured by the OEM. May include manufacturer certification or company certification. |
NS | New Surplus. New material item purchased from excess inventory. |
OH | Overhauled. Product has been rebuilt and tested in accordance with the manufacturer's specifications by a repair shop (MRO). |
SV | Serviceable product. |
AR | As Removed. Product removed from aircraft or platform with no guarentee on the functionality of the part. |
RP | Repairable. Product can be repaired by a MRO and be given a FAA 8130 or EASA Form 1 certification. |