Part Number 950-1219-400

Power Transformer

Pricing & Availability

Submit this form for current pricing and availability of this NSN.
Part / NSN:
Qty:
Your Email:
Phone:
Ref. / PO #:
Company:
Your Name:

We do not share or sell your information to anyone.
Privacy | Terms

All major credit cards accepted as well as gov. p-cards
Part Number
DEMIL
Shelf Life
UOM
NIIN
Part:
950-1219-400
Demil:
No
Shelf Life:
UOM:
NIIN:
000690314

Part Information
1 primary winding; 9 secondary windings

NSN
National Stock Number:
5950-00-069-0314 5950000690314
TXT
Description:
Power Transformer
INC
INC
Item Name Code:
32496
MRC:
An indication that the level of probability that an item will operate without failure,at a specified rated capability,at a specified temperature,and for a specified period of time,has been established by testing random samples of production lot.AARG
Reliability Indicator:
Not established
MRC:
The distance between the center of one mounting facility and the center of the adjacent mounting facility parallel to the length.ABKQ
Center To Center Distance Between Mounting Facilities Parallel To Length:
5.047 inches single mounting facility single center group and 5.078 inches single mounting facility single center group
MRC:
The distance between the center of one mounting facility and the center of the adjacent mounting facility parallel to the width.ABKR
Center To Center Distance Between Mounting Facilities Parallel To Width:
3.995 inches single mounting facility single center group and 4.005 inches single mounting facility single center group
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
5.531 inches
MRC:
The length of a straight line which passes through the center of a mounting hole,and terminates at the circumference.ABTB
Mounting Hole Diameter:
0.203 inches single group
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
45.0 hertz single component and 430.0 hertz single component
MRC:
The relationship of the phase input to the phase output of an alternating current.ACZC
Input-output Phase Relationship:
Single phase to single phase single component
MRC:
The means by which a protective metal screen,plate,or inclosure is placed around or between the windings of an item to prevent electrostatic or magnetic coupling.ACZX
Winding Shielding Method:
Internal shield grounded to inclosure and core single component
MRC:
A measurement of the longest dimension of the body,in distinction from width.ADAQ
Body Length:
Between 5.406 inches and 5.468 inches
MRC:
A measurement taken at right angles to the length of the body,in distinction from thickness.ADAT
Body Width:
Between 5.031 inches and 5.093 inches
MRC:
The maximum temperature at which the item is rated to operate for an extended period of time.AEHZ
Maximum Operating Temp:
105.0 degrees celsius
MRC:
Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
Inclosure Type:
Hermetically sealed
MRC:
The number of mounting facilities provided.AKPV
Mounting Facility Quantity:
10 single group
MRC:
The means of attaching the item.AXGY
Mounting Method:
Flange single group and unthreaded hole single group
MRC:
The purpose and the total number of individual (not electrically connected) windings designed to perform in a transformer.BPLC
Winding Function And Quantity:
1 primary single component and 9 secondary single component
MRC:
The amount of operating current for which the winding is designed.CRBZ
Winding Operating Current:
0.3 amperes ac single component 3rd secondary
MRC:
The amount of operating current for which the winding is designed.CRBZ
Winding Operating Current:
1.0 amperes ac single component 2nd secondary
MRC:
The amount of operating current for which the winding is designed.CRBZ
Winding Operating Current:
1.2 amperes ac single component 1st secondary
MRC:
The amount of operating current for which the winding is designed.CRBZ
Winding Operating Current:
1.4 amperes ac single component 4th secondary
MRC:
The value/s/ of the operating voltage applied to the winding.CWJS
Winding Operating Voltage:
115.00 ac volts single component single primary
MRC:
The value/s/ of the operating voltage applied to the winding.CWJS
Winding Operating Voltage:
19.80 ac volts single component 4th secondary
MRC:
The value/s/ of the operating voltage applied to the winding.CWJS
Winding Operating Voltage:
28.20 ac volts single component 3rd secondary
MRC:
The value/s/ of the operating voltage applied to the winding.CWJS
Winding Operating Voltage:
46.00 ac volts single component 2nd secondary
MRC:
The value/s/ of the operating voltage applied to the winding.CWJS
Winding Operating Voltage:
76.80 ac volts single component 1st secondary
MRC:
The specification,standard,drawing,or similar instrument that specifies environmental and performance requirements or test conditions under which an item is tested and establishes acceptable limits within which the item must conform identified by an alphabetic and/or numeric reference number. includes the commercial and government entity (cage) code of the entity controlling the instrument.TEST
Test Data Document:
13499-672-0135-000 drawing (this is the basic governing drawing, such as a contractor drawing, original equipment manufacturer drawing, etc.; excludes any specification, standard or other document that may be referenced in a basic governing drawing)
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
29 solder stud

Similar Power Transformers

« Coils and Transformers Catalog
Compare Now »
Clear | Hide