Part Number
DEMIL
Shelf Life
UOM
NIIN
Part Information
9500b/3200 3.2 ghz high-performance oscilloscope calibration workstation
NSN
National Stock Number:
TXT
Description:
Oscilloscope Calibrator
MRC:
An overall measurement between specified points of an item,in distinction from height.ABFY
Overall Depth:
17.300 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
5.240 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
16.800 inches
MRC:
The value,or range of values,of root mean square potential for which the item is rated.ACYN
Ac Voltage Rating:
110.0 volts
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
60.0 hertz
MRC:
Indicates the type of calibration provided.BDHR
Calibration Type:
Dc voltage and peak pulse power and peak to peak current and peak to peak voltage and variable output
MRC:
An indication of the calibration measurement range of the instrument.BDHS
Instrument Calibration Range:
Dc voltage 1mvdc-200vdc; amplitude 40uv-200v peak to peak into 1 meg ohm, 40uv-5v peak to peak into 50 ohm (both w/ freq range 10 hz to 100 khz; pulse (low-edge) 5mv-3v peak to peak into 50 ohm 10 hz to 2mhz, (high-edge) 1mv-200v peak to peak into 1 meg ohm & 1mv-5v peak to peak into 50 ohm 10 hz to 100 khz; current porm 100ua to porm 100ma 10 hz to 100 khz
MRC:
The number of alternating current phases.FAAZ
Phase:
Single
MRC:
Those unusual or unique characteristics or qualities of an item not covered in the other requirements and which are determined to be essential for identification.FEAT
Special Features:
Can be usd with fluke ieee 48 (gpib) based met/cal automated calibration management software; oscilloscope calibration system is comprised of 9500b/3200 workstation, 4 each of 9530 fast output heads, a 9550 fast acting head, a 9560 activ head, a 9500-4955 dmm calibration interface adapter and a 9500-90 rack mount kit. Calibration system operates over frequency range of 0.1 hz to 3.2 ghz and 0.1 hz to 6.4 ghz using the 9560 active head
MRC:
The physical configuration of the item.SHPE
Shape:
Rectangular
MRC:
Characteristics or qualities of an item,not covered in any other requirement,which are considered essential information for one or more functions excluding nsn assignment.SUPP
Supplementary Features:
Remarks: engineer: lynne lewellen/mlee/dsn: 366-5121, planner: jim ferry/mlsp/dsn: 366-5081; the 9500b/3200/af will be procured with afmetcal funds under budget activity bp841010 (other base maintenance and support equipment) (base/alc calibration package). The system will be supplied at no cost to the base precision measurement equipment laboratory (pmel) to be used in the pmel. This system will not be used in direct support of any specific weapons system. The nature of this equipment dictates a budget code m