Part Number 953-1-2M1

Motor Controller

Pricing & Availability

Submit this form for current pricing and availability of this NSN.
Part / NSN:
Qty:
Your Email:
Phone:
Ref. / PO #:
Company:
Your Name:

We do not share or sell your information to anyone.
Privacy | Terms

All major credit cards accepted as well as gov. p-cards
Part Number
DEMIL
Shelf Life
UOM
NIIN
Part:
953-1-2m1
Demil:
No
Shelf Life:
UOM:
NIIN:
000799904
NSN
National Stock Number:
6110-00-079-9904 6110000799904
TXT
Description:
Motor Controller
INC
INC
Item Name Code:
00904
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
28.200 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
62.000 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
18.500 inches
MRC:
The means by which the item is actuated.AFLW
Actuation Method:
Magnetic
MRC:
Indicates the performance capability of the item or component.AGLD
Performance Type:
Semiautomatic
MRC:
The number of fuses the item is designed to accommodate /including spares/.AGUE
Fuse Accommodation Quantity:
2
MRC:
The working period under which the item was designed to operate.AKPS
Duty Cycle:
Intermittent
MRC:
The pattern or arrangement that describes the mounting configuration of the item.ALGC
Mounting Configuration:
Eight 0.500 in. Diameter mtg holes 2 rows 9.750 in. Apart 4 holes ea row 7 in. C to c
MRC:
An indication of the characteristic of the operating voltage.ANCN
Operating Voltage Characteristic:
Reduced
MRC:
The means used to reduce the electrical voltage.ANCP
Voltage Reduction Method:
Resistor
MRC:
The means used to restore the item to its full voltage.ANCQ
Full Voltage Restoring Method:
Time limit acceleration
MRC:
An indication of the rated horsepower of the item.ANCY
Horsepower Rating:
12.500
MRC:
The voltage required to actuate the item.ANDE
Actuator Voltage:
115.0 dc
MRC:
Indicates the type of load for which the item is protected.ANDW
Load Protection Type:
Undervoltage
MRC:
The temperature of the medium surrounding an item at which it can be operated.ANDX
Ambient Temp:
40.0 degrees celsius
MRC:
An indication of the feature/s/ of the inclosure.ANPZ
Inclosure Feature:
Watertight
MRC:
Indicates the type of control.AQZF
Control Type:
Remote
MRC:
Those features,not otherwise specified,which may be required for proper functioning of the item.CBBL
Features Provided:
Reversible and circuit protection fuse

Similar Motor Controllers

« Electrical Control Equipment Catalog
Compare Now »
Clear | Hide