Part Number
DEMIL
Shelf Life
UOM
NIIN
NSN
National Stock Number:
TXT
Description:
Variable Attenuator
MRC:
The primary application for which the item is designed.AAFS
Application Design:
Transmission line
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the body.AAQL
Body Style:
Coaxial type
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
14.125 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
1.070 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
1.220 inches
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
Age countermeasure sets, qrc335, alq101v
MRC:
The ratio of the maximum to the minimum amplitude of pressure /voltage/ measured along the path of the waves.AHTW
Voltage Standing Wave Ratio:
1.50 and 1.60
MRC:
A letter or group of letters used to designate the particular coaxial connector series.AHUC
Coaxial Connector Series Designation:
N
MRC:
The amount of electrical energy that can be dissipated.AJDB
Power Rating:
1.0 watts average and 1.0 kilowatts peak
MRC:
The mathematical relationship of power available at the load before and after addition of the item to the circuit,set to its lowest value of attenuation,expressed in maximum decibels.ASYC
Insertion Loss At Minimum Attenuation In Maximum Decibels:
1.0
MRC:
The overall limits of decrease of the amplitude ratio of a signal between the input and output of the item,expressed in decibels.ASYD
Overall Attenuation Range In Decibels:
+0.0/+20.0
MRC:
The overall limits of decrease of the amplitude ratio of a signal between the input and output of the item,expressed in decibels.ASYD
Overall Attenuation Range In Decibels:
+0.0 to 20.0
MRC:
The means by which the attenuation can be varied from the minimum to the maximum setting.ASYF
Attenuation Variation Method:
Continuous
MRC:
Indicates the type and number of facilities by which the item is mounted.AXHR
Mounting Facility Type And Quantity:
2 connector
MRC:
The minimum and maximum cyclic changes,per unit of time,for which an item is rated.BNGR
Frequency Range:
Between 2.500 gigahertz and 11.000 gigahertz
MRC:
The overall limits of permissible variation in the attenuation accuracy from the nominal value at a specified frequency rating or range,expressed in decibels.BQNR
Overall Attenuation Accuracy In Decibels:
-1.00/+1.20
MRC:
Indicates the type and number of facilities for adjusting the item.CQTQ
Adjustment Device Type And Quantity:
1 lever
MRC:
The total opposition (resistive and reactive) to the flow of alternating current,expressed in ohms.CTGG
Impedance Rating In Ohms:
50.0 input-output
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
1 connector, coaxial, female and 1 connector, coaxial, male