Part Number 9902771331

Multimeter
Stock Availability  condition code chart

Part number 9902771331 is in stock in the following quantities and conditions.

  • NE: 2
  • NS: 1
  • AR: 1
  • SV: 1

Note: Availability of this item was last updated 01/14/2022 and may have changed since then. Request a quote for up to date pricing and availability.

Pricing & Availability

Submit this form for current pricing and availability of this NSN.
Part / NSN:
Qty:
Your Email:
Phone:
Ref. / PO #:
Company:
Your Name:

We do not share or sell your information to anyone.
Privacy | Terms

All major credit cards accepted as well as gov. p-cards
Part Number
DEMIL
Shelf Life
UOM
NIIN
Part:
9902771331
Demil:
No
Shelf Life:
UOM:
NIIN:
011318586

Part Information
Critical appl-trans; radar set, an/tps-32; tac air opn cntl, an/tyq-2

NSN
National Stock Number:
6625-01-131-8586 6625011318586
TXT
Description:
Multimeter
INC
INC
Item Name Code:
00794
MRC:
The type of electrical circuit in which the item is designed to be used.AACT
Circuit Current For Which Designed:
Dc
MRC:
An overall measurement between specified points of an item,in distinction from height.ABFY
Overall Depth:
1.800 inches
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
7.100 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
3.400 inches
MRC:
The environmental elements or conditions that an item is designed or protected to resist or withstand satisfactorily.ADZC
Environmental Protection:
Cold resistant and heat resistant and shock resistant and vibration resistant and water resistant
MRC:
The name and number of those parts furnished with the item of supply that have not been specified elsewhere.AKYN
Furnished Items And Quantity:
Manual 1; test lead 2; 9 v btry 1; oper card 1; fuse 1; cal certificate 1
MRC:
Indicates the type of device used to register the condition(s).AMKD
Indicator Type:
Digital display
MRC:
The installation for which the item is designed.AMQY
Installation Design:
Hand held
MRC:
The minimum and maximum frequencies to which the item will respond without exceeding its accuracy rating.ANSY
Frequency Response Range:
+48.000/+450.000 hertz
MRC:
The hue or tint of the background.AQFY
Background Color:
Gray single indicator all ranges
MRC:
The source of power which provides the energy required for the operation of the item.AWZJ
Power Source:
Internal
MRC:
Indicates the type of display provided.BFQN
Display Type:
Liquid crystal
MRC:
The number of digits displayed.BFQP
Display Digit Quantity:
3-1/2
MRC:
The minimum to maximum value which the item is capable of measuring.BHMW
Measurement Range:
+0.0/+1000.0 volts, dc single indicator 16th range
MRC:
The minimum to maximum value which the item is capable of measuring.BHMW
Measurement Range:
+0.0/+2.0 kilohms single indicator 1st range
MRC:
The minimum to maximum value which the item is capable of measuring.BHMW
Measurement Range:
+0.0/+2.0 milliamperes, dc single indicator 7th range
MRC:
The minimum to maximum value which the item is capable of measuring.BHMW
Measurement Range:
+0.0/+2.0 milliamperes, ac single indicator 4th range
MRC:
The minimum to maximum value which the item is capable of measuring.BHMW
Measurement Range:
+0.0/+2.0 volts, ac single indicator 12th range
MRC:
The minimum to maximum value which the item is capable of measuring.BHMW
Measurement Range:
+0.0/+2.0 volts, dc single indicator 15th range
MRC:
The minimum to maximum value which the item is capable of measuring.BHMW
Measurement Range:
+0.0/+20.0 megohms single indicator 3rd range
MRC:
The minimum to maximum value which the item is capable of measuring.BHMW
Measurement Range:
+0.0/+20.0 milliamperes, ac single indicator 5th range
MRC:
The minimum to maximum value which the item is capable of measuring.BHMW
Measurement Range:
+0.0/+200.0 millivolts, dc single indicator 10th range
MRC:
The minimum to maximum value which the item is capable of measuring.BHMW
Measurement Range:
+0.0/+200.0 ohms single indicator 11th range
MRC:
The minimum to maximum value which the item is capable of measuring.BHMW
Measurement Range:
+0.0/+200.0 millivolts, ac single indicator 9th range
MRC:
The minimum to maximum value which the item is capable of measuring.BHMW
Measurement Range:
+0.0/+200.0 volts, ac single indicator 13th range
MRC:
The minimum to maximum value which the item is capable of measuring.BHMW
Measurement Range:
+0.0/+2000.0 kilohms single indicator 2nd range
MRC:
The minimum to maximum value which the item is capable of measuring.BHMW
Measurement Range:
+0.0/+2000.0 milliamperes, ac single indicator 6th range
MRC:
The minimum to maximum value which the item is capable of measuring.BHMW
Measurement Range:
+0.0/+2000.0 milliamperes, dc single indicator 8th range
MRC:
The minimum to maximum value which the item is capable of measuring.BHMW
Measurement Range:
+0.0/+750.0 volts, ac single indicator 14th range
MRC:
The means provided for selecting a scale.BLSB
Scale Selection Method:
Switch and terminal
MRC:
Those features,not otherwise specified,which may be required for proper functioning of the item.CBBL
Features Provided:
Electrical overload protection and internal battery accommodation and portable and warning feature
MRC:
The master requirement codes of those requirements which are technically critical by reason of tolerance,fit,performance,or other characteristics which affect identification of the item.CRTL
Criticality Code Justification:
Feat
MRC:
The deviation from a standard or true value for which the item is rated.CTPT
Accuracy Rating:
Poam 5.0 pct of reading plus 5 digits single indicator 9th range
MRC:
The deviation from a standard or true value for which the item is rated.CTPT
Accuracy Rating:
Porm 0.1 pct of reading plus 1 digit single indicator 10th range
MRC:
The deviation from a standard or true value for which the item is rated.CTPT
Accuracy Rating:
Porm 0.1 pct of reading plus 1 digit single indicator 15th range
MRC:
The deviation from a standard or true value for which the item is rated.CTPT
Accuracy Rating:
Porm 0.1 pct of reading plus 1 digit single indicator 16th range
MRC:
The deviation from a standard or true value for which the item is rated.CTPT
Accuracy Rating:
Porm 0.1 pct of reading plus 1 digit single indicator 1st range
MRC:
The deviation from a standard or true value for which the item is rated.CTPT
Accuracy Rating:
Porm 0.15 pct of reading plus 1 digit single indicator 2nd range
MRC:
The deviation from a standard or true value for which the item is rated.CTPT
Accuracy Rating:
Porm 0.2 pct of reading plus 3 digits single indicator 11th range
MRC:
The deviation from a standard or true value for which the item is rated.CTPT
Accuracy Rating:
Porm 0.75 pct of reading plus 1 digit single indicator 7th range
MRC:
The deviation from a standard or true value for which the item is rated.CTPT
Accuracy Rating:
Porm 0.75 pct of reading plus 1 digit single indicator 8th range
MRC:
The deviation from a standard or true value for which the item is rated.CTPT
Accuracy Rating:
Porm 1.0 pct of reading plus 2 digits single indicator 14th range
MRC:
The deviation from a standard or true value for which the item is rated.CTPT
Accuracy Rating:
Porm 1.5 pct of reading plus 2 digits single indicator 5th range
MRC:
The deviation from a standard or true value for which the item is rated.CTPT
Accuracy Rating:
Porm 1.5 pct of reading plus 2 digits single indicator 6th range
MRC:
The deviation from a standard or true value for which the item is rated.CTPT
Accuracy Rating:
Porm 1.5 pct of reading plus 3 digits single indicator 13th range
MRC:
The deviation from a standard or true value for which the item is rated.CTPT
Accuracy Rating:
Porm 2.0 pct of reading plus 1 digit single indicator 3rd range
MRC:
The deviation from a standard or true value for which the item is rated.CTPT
Accuracy Rating:
Porm 3.0 pct of reading plus 2 digits single indicator 4th range
MRC:
The deviation from a standard or true value for which the item is rated.CTPT
Accuracy Rating:
Porm 5.0 pct of reading plus 5 digits single indicator 12th range
MRC:
The hue or tint of the display.CTQH
Display Color:
Black single indicator all ranges
MRC:
The means provided for electrical connection to a circuit and the number of each type of connection.CTTD
Circuit Attachment Method And Quantity:
3 wire lead
MRC:
The value(s) of root mean square or direct current potential which must be applied to the item for operation,expressed in volts.CTWN
Operating Voltage Rating In Volts:
9.0 dc
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Plastic
MRC:
An indication of the nuclear hardness criticality of the item.NHCF
Nuclear Hardness Critical Feature:
Nonhardened
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the item.STYL
Style Designator:
Hand-held
MRC:
A measurement of volume taken by multiplying the length by the width by the height of the unit of issue and rendered in cubic units.SUCB
Unit Of Issue Cube:
0.025 cubic feet
MRC:
Characteristics or qualities of an item,not covered in any other requirement,which are considered essential information for one or more functions excluding nsn assignment.SUPP
Supplementary Features:
Visual and audible continuity; peak-hold; level detection; conductance; diode test
MRC:
The justification for the assignment of a federal supply class /fsc/ to an item based on the classification of the next higher classifiable assembly.ZZZV
Fsc Application Data:
Test set, elect. Equip.

Similar Multimeters

« Electrical and Electronic Properties Measuring and Testing Instruments Catalog
Compare Now »
Clear | Hide