Part Number
DEMIL
Shelf Life
UOM
NIIN
Part:
998-1107-a-28
Demil:
No
Shelf Life:
UOM:
NIIN:
015334474

Part Information
Pump, recirculating

NSN
National Stock Number:
4320-01-533-4474 4320015334474
TXT
Description:
Centrifugal Pump Unit
INC
INC
Item Name Code:
17988
MRC:
The number of prime movers incorporated in the unit.AAXH
Prime Mover Quantity:
1
MRC:
Indicates the type of current whether alternating,direct,or both.ACDC
Current Type:
Ac
MRC:
The type of service with which the item is designed to be used.ACKL
Media For Which Designed:
Water, fresh
MRC:
The number of pumps incorporated in the item.AENC
Pump Quantity:
1
MRC:
The maximum rated capacity delivered by the item.AHYV
Maximum Discharge Flow Rate:
20.0 gallons per minute
MRC:
The sum of the total discharge head and the total suction lift.AHYX
Total Head:
46.200 feet
MRC:
The position in which the pumping element/s/ is designed to operate.AHZA
Pumping Element Operating Position:
Horizontal
MRC:
The number of impellers incorporated in the centrifugal pump.AHZF
Centrifugal Pump Impeller Quantity:
1
MRC:
Indicates the type of prime mover included with the unit.AKDJ
Prime Mover Type:
Electric motor
MRC:
The rated power of the prime mover.CSYL
Prime Mover Power Rating:
1.5 horsepower
MRC:
The total electrical voltage.ELEC
Voltage In Volts:
440.0
MRC:
The number of alternating current phases.FAAZ
Phase:
Three
MRC:
Those unusual or unique characteristics or qualities of an item not covered in the other requirements and which are determined to be essential for identification.FEAT
Special Features:
Pump size 1.25 x 1 x 7 close-coupled with 1.25in. Suction class 150 flange ansi b16.5, 1in. Discharge class 150 flange ansi b16.5; pump impeller finish diameter 4in.; orifice diameter .687in.; submergence flooded; suction temperature 110 degrees f; rated input .7 (est); max. Rated input at any condition 1.0 (est); hydrostatic test pressure 50 psi/30 min.; motor constant speed, continuous duty per mil-m-1760e; output 1/5 bhp; speed (sych) 3600 rpm; windings squirrel cage; permissible ambient temperature 50 degrees c; enclosure tefc; bearings ball; frame 184tncz; motor mounting horizontal
MRC:
The cycles per second /hertz/ of the alternating current.FREQ
Frequency In Hertz:
60.0