Part Number 998-246B-0-01

Centrifugal Pump Unit

Pricing & Availability

Submit this form for current pricing and availability of this NSN.
Part / NSN:
Qty:
Your Email:
Phone:
Ref. / PO #:
Company:
Your Name:

We do not share or sell your information to anyone.
Privacy | Terms

All major credit cards accepted as well as gov. p-cards
Part Number
DEMIL
Shelf Life
UOM
NIIN
Part:
998-246b-0-01
Demil:
No
Shelf Life:
UOM:
NIIN:
015053707

Part Information
Material: duplex ss iaw astm-f998, mechanical seal to astm f1511, suction temperature: 32-100 degrees f., weight: pump 1192 lbs, motor 1708 lbs, assembly 2900 lbs

NSN
National Stock Number:
4320-01-505-3707 4320015053707
TXT
Description:
Centrifugal Pump Unit
INC
INC
Item Name Code:
17988
MRC:
The number of prime movers incorporated in the unit.AAXH
Prime Mover Quantity:
1
MRC:
The number of stages incorporated in the item.AAYD
Stage Quantity:
10
MRC:
The number of discharge connections included on the item.AAYV
Discharge Connection Quantity:
1
MRC:
Indicates the type of discharge connection included on the item.AAYW
Discharge Connection Type:
Round flange
MRC:
Indicates the type of current whether alternating,direct,or both.ACDC
Current Type:
Ac
MRC:
The type of service with which the item is designed to be used.ACKL
Media For Which Designed:
Water, salt
MRC:
The number of pumps incorporated in the item.AENC
Pump Quantity:
1
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
Ican, wsd: nimitz class cvn
MRC:
The maximum rated capacity delivered by the item.AHYV
Maximum Discharge Flow Rate:
187.0 gallons per minute
MRC:
The sum of the total discharge head and the total suction lift.AHYX
Total Head:
1480.000 feet
MRC:
The position in which the pumping element/s/ is designed to operate.AHZA
Pumping Element Operating Position:
Horizontal
MRC:
The number of impellers incorporated in the centrifugal pump.AHZF
Centrifugal Pump Impeller Quantity:
10
MRC:
Indicates the type of prime mover included with the unit.AKDJ
Prime Mover Type:
Electric motor
MRC:
The rated power of the prime mover.CSYL
Prime Mover Power Rating:
150.0 horsepower
MRC:
The total electrical voltage.ELEC
Voltage In Volts:
440.0
MRC:
The number of alternating current phases.FAAZ
Phase:
Three
MRC:
The cycles per second /hertz/ of the alternating current.FREQ
Frequency In Hertz:
60.0