Part Number
DEMIL
Shelf Life
UOM
NIIN
NSN
National Stock Number:
TXT
Description:
Power Transformer
MRC:
An indication that the level of probability that an item will operate without failure,at a specified rated capability,at a specified temperature,and for a specified period of time,has been established by testing random samples of production lot.AARG
Reliability Indicator:
Not established
MRC:
The distance between the center of one mounting facility and the center of the adjacent mounting facility parallel to the length.ABKQ
Center To Center Distance Between Mounting Facilities Parallel To Length:
5.875 inches single mounting facility single center group
MRC:
The distance between the center of one mounting facility and the center of the adjacent mounting facility parallel to the width.ABKR
Center To Center Distance Between Mounting Facilities Parallel To Width:
3.125 inches single mounting facility single center group
MRC:
A measurement taken at right angles to the length of the mounting slot,in distinction from thickness.ABTD
Mounting Slot Width:
0.297 inches single group
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
60.0 hertz single component
MRC:
The relationship of the phase input to the phase output of an alternating current.ACZC
Input-output Phase Relationship:
Single phase to single phase single component
MRC:
The maximum amount of power for which the transformer is rated.ACZF
Maximum Transformer Power Rating:
100.0 volt-ampere single component
MRC:
A measurement of the longest dimension of the body,in distinction from width.ADAQ
Body Length:
Between 6.740 inches and 6.760 inches
MRC:
A measurement taken at right angles to the length of the body,in distinction from thickness.ADAT
Body Width:
4.000 inches
MRC:
A measurement from the bottom to the top of the body,in distinction from depth.ADAU
Body Height:
4.000 inches
MRC:
The maximum temperature at which the item is rated to operate for an extended period of time.AEHZ
Maximum Operating Temp:
125.0 degrees celsius
MRC:
Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
Inclosure Type:
Fully enclosed
MRC:
The number of mounting facilities provided.AKPV
Mounting Facility Quantity:
3 single group
MRC:
The means of attaching the item.AXGY
Mounting Method:
Flange single group and slot single group
MRC:
The means of cooling used to maintain the required operating temperature of the item.BFMF
Cooling Method:
Self-cooled
MRC:
The purpose and the total number of individual (not electrically connected) windings designed to perform in a transformer.BPLC
Winding Function And Quantity:
1 primary single component and 1 secondary single component
MRC:
The distance between the center of one mounting facility and the center of the adjacent mounting facility parallel to the base of an isosceles triangle.CQKH
Center To Center Distance Between Mounting Facilities Parallel To The Base Of An Isosceles Triangle:
3.115 inches single mounting facility single center group and 3.135 inches single mounting facility single center group
MRC:
The distance between the center of one mounting facility and the center of the adjacent mounting facility parallel to the altitude of an isosceles triangle.CSQJ
Center To Center Distance Between Mounting Facilities Parallel To The Altitude Of An Isosceles Triangle:
5.865 inches single mounting facility single center group and 5.885 inches single mounting facility single center group
MRC:
The value/s/ of the operating voltage applied to the winding.CWJS
Winding Operating Voltage:
110.00 ac volts single component single secondary
MRC:
The value/s/ of the operating voltage applied to the winding.CWJS
Winding Operating Voltage:
440.00 ac volts single component single primary
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
4 wire lead