Part Number
DEMIL
Shelf Life
UOM
NIIN
Part Information
Positive displacement meter with 6 inch 300 pound flanged connections capable of handling diseal fuel, automotive gasoline, aviation gasoline and aviation jet fuels at a flow rate of 600 gpm; includes a digital readout register that indicates the gallonage; the register is mounted on the meter; length 21 inches; width 26.5inches, height 24.5 inches
NSN
National Stock Number:
TXT
Description:
Volumetric Positive Displa Meter
MRC:
The type of service with which the item is designed to be used.ACKL
Media For Which Designed:
Aircraft fuel
MRC:
A narrative description of the type of inlet connection.ACQW
Inlet Connection Type:
Drilled flange
MRC:
A measurement of the smallest dimension of an inlet flange,in distinction from length or width.ACRF
Inlet Flange Thickness:
1.190 inches
MRC:
The number of inlet bolt holes on the item.ACRL
Inlet Bolt Hole Quantity:
12
MRC:
The length of a straight line which passes through the center of an inlet bolt hole,and terminates at the circumference.ACRM
Inlet Bolt Hole Diameter:
0.880 inches
MRC:
The length of a straight line which passes through the center of an inlet bolt circle,and terminates at the circumference.ACRN
Inlet Bolt Circle Diameter:
10.620 inches
MRC:
The maximum temperature at which the item is rated to operate for an extended period of time.AEHZ
Maximum Operating Temp:
160.0 degrees fahrenheit
MRC:
The installation for which the item is designed.AMQY
Installation Design:
Direct mount
MRC:
Designates the size of the inlet connection included on the item.ANHY
Inlet Connection Size:
6.0 in.
MRC:
An indication of the unit of measure for which the item is designed.ANSX
Measurement Unit:
Gallon
MRC:
The minimum and maximum numeric values representing the measurement coverage of a scale.ANSZ
Scale Measurement Range:
+0.0/+99999.0
MRC:
A narrative description of the type of outlet connection.ARTH
Outlet Connection Type:
Drilled flange
MRC:
The smallest numeric figure the item will register.AXEA
Smallest Increment Indicated:
0.50
MRC:
Indicates the displacement type.AXFP
Displacement Type:
Rotor
MRC:
Indicates the location for which the item is designed to be installed.AYNY
Installation Location:
Any acceptable
MRC:
The volume of liquid flowing through the item in a given period of time.BHCC
Liquid Flow Rate:
600.0 gallons per minute
MRC:
Indicates the type of register provided on the item.BHCG
Register Type:
Wheel
MRC:
An indication of whether or not the item is provided with a reset feature.BHCH
Reset Feature:
Provided
MRC:
An indication of whether or not the item is provided with a printing mechanism.BHCJ
Printing Mechanism:
Not provided
MRC:
An indication of whether or not the inlet is provided with a union connection.BHCL
Inlet Union Connection:
Not provided
MRC:
Designates the size of the outlet connection included on the item.BHCM
Outlet Connection Size:
6.0 in.
MRC:
A measurement of the smallest dimension of an outlet flange,in distinction from length or width.BHCR
Outlet Flange Thickness:
1.000 inches
MRC:
The length of a straight line which passes through the center of an outlet bolt circle,and terminates at the circumference.BHCS
Outlet Bolt Circle Diameter:
10.620 inches
MRC:
The number of outlet bolt hole(s) on the item.BHCT
Outlet Bolt Hole Quantity:
12
MRC:
The length of a straight line which passes through the center of an outlet bolt hole,and terminates at the circumference.BHCW
Outlet Bolt Hole Diameter:
0.880 inches
MRC:
An indication of whether or not the outlet is provided with a union connection.BHCX
Outlet Union Connection:
Not provided