Part Number A-A-59381

Ohmmeter

Pricing & Availability

Submit this form for current pricing and availability of this NSN.
Part / NSN:
Qty:
Your Email:
Phone:
Ref. / PO #:
Company:
Your Name:

We do not share or sell your information to anyone.
Privacy | Terms

All major credit cards accepted as well as gov. p-cards
Part Number
DEMIL
Shelf Life
UOM
NIIN
Part:
a-a-59381
Demil:
No
Shelf Life:
UOM:
NIIN:
015089529

Part Information
Soil resistance meter aka soil resistivity test kit

NSN
National Stock Number:
6625-01-508-9529 6625015089529
TXT
Description:
Ohmmeter
INC
INC
Item Name Code:
00494
MRC:
The type of electrical circuit in which the item is designed to be used.AACT
Circuit Current For Which Designed:
Dc
MRC:
The maximum voltage the insulating materials of the item will withstand without resulting in disruptive discharge or deterioration,expressed in volts.AAPB
Dielectric Withstanding Voltage In Volts:
1500.0
MRC:
The environmental elements or conditions that an item is designed or protected to resist or withstand satisfactorily.ADZC
Environmental Protection:
Dripproof and splash proof
MRC:
The name and number of those parts furnished with the item of supply that have not been specified elsewhere.AKYN
Furnished Items And Quantity:
Kit shall include all the equipmeneccessary to calculate the resistivity of the soil by the wenner four-pin and soil method outlined by the astm g 57-78 standard. Kit shall include four-pin resistivity test reel w/leads, four stainless steel t-handle pins 3/8" x 18", soil box w/ four soil pins, operator, maint, and ipb manuals, case
MRC:
An indication of the accuracy of an item,expressed in percent.APPN
Accuracy In Percent:
-1.0/+1.0 at full scale single indicator single range
MRC:
The source of power which provides the energy required for the operation of the item.AWZJ
Power Source:
Internal
MRC:
Those unusual or unique characteristics or qualities of an item not covered in the other requirements and which are determined to be essential for identification.FEAT
Special Features:
Johmmeter/test kit shall be capable of resultant resitivity measurement depth of 20 ft by use of four electrode method; shall be capable of two, three, or four terminal method; calibration interval of 12 months

Similar Ohmmeters

« Electrical and Electronic Properties Measuring and Testing Instruments Catalog
Compare Now »
Clear | Hide