Part Number
DEMIL
Shelf Life
UOM
NIIN
Part Information
With 10 ft type 316 stainless steel flexible cable stem, desplacement type liquid level control, explosion proof and waterproof switch housing and designed for 3/4 in. Conduit wiring
NSN
National Stock Number:
TXT
Description:
Liquid Level Switch
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
Any acceptable
MRC:
The length measured from the element to the extreme end of the power cable.ABJP
Power Cable Length:
Any acceptable
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
Any acceptable
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
Any acceptable
MRC:
The value,or range of values,of root mean square potential for which the item is rated.ACYN
Ac Voltage Rating:
230.000 volts
MRC:
A measurement of the longest straight line across a circular cross-sectional plane.ADAV
Overall Diameter:
Any acceptable
MRC:
The means by which the item is actuated.AFLW
Actuation Method:
Buoyancy
MRC:
Indicates the type of electrical connection included on the item.AGBD
Electrical Connection Type:
Cable
MRC:
An indication of whether or not a facility/ies/ to accommodate a battery/ies/ is included.ALSF
Internal Battery Accommodation:
Not included
MRC:
The amount of current at maximum rated voltage for which the item is designed.APGW
Current Rating At Maximum Rated Voltage:
6.5 amperes resistive load
MRC:
The number of floats provided.AWAE
Float Quantity:
2
MRC:
The temperature at which the item operates.AWTN
Operating Tempurature Rating:
Between 100.0 degrees fahrenheit and 400.0 degrees fahrenheit
MRC:
The means of attaching the item.AXGY
Mounting Method:
Thread
MRC:
The installed position for which the item is designed.BBJX
Mounting Position:
Vertical
MRC:
The designation that identifies the schematic diagram of the contact arrangement.BJKD
Contact Arrangement:
Spst normally open
MRC:
An indication of whether or not a relay is included.BJKG
Relay:
Not included
MRC:
Indicates the type of liquid(s) for which the item is designed.BJKH
Liquid Type For Which Designed:
Diesel oil
MRC:
The distance of the effective travel of the float.BJKN
Float Effective Travel:
2.000 inches
MRC:
The mounting dimensions of the item.BJKP
Mounting Dimensions:
2-1/2 -8 npt thd connection
MRC:
A measurement of the longest dimension from the mounting surface to the end of the item,which is designed to be inserted into the tank.BJKQ
Tank Insertion Length:
Any acceptable
MRC:
The number of alternating current phases.FAAZ
Phase:
Single