Part Number A19ANC-2

Thermostatic Switch

Pricing & Availability

Submit this form for current pricing and availability of this NSN.
Part / NSN:
Qty:
Your Email:
Phone:
Ref. / PO #:
Company:
Your Name:

We do not share or sell your information to anyone.
Privacy | Terms

All major credit cards accepted as well as gov. p-cards
Part Number
DEMIL
Shelf Life
UOM
NIIN
Part:
a19anc-2
Demil:
No
Shelf Life:
UOM:
NIIN:
012234000
NSN
National Stock Number:
5930-01-223-4000 5930012234000
TXT
Description:
Thermostatic Switch
INC
INC
Item Name Code:
00451
MRC:
A measurement of the longest dimension of the body,in distinction from width.ADAQ
Body Length:
4.080 inches
MRC:
A measurement from the bottom to the top of the body,in distinction from depth.ADAU
Body Height:
4.080 inches
MRC:
The length of a straight line which passes through the center of an unthreaded mounting hole,and terminates at the circumference.AEBV
Unthreaded Mounting Hole Diameter:
0.280 inches
MRC:
A measurement of the longest dimension of a capillary tube.AEVT
Capillary Tube Length:
120.0 inches
MRC:
A measurement of the longest dimension of a bulb.AEVU
Bulb Length:
2.500 inches
MRC:
The length of a straight line which passes through the center of the bulb,and terminates at the circumference.AEVV
Bulb Diameter:
0.290 inches
MRC:
The longest distance between mounting centers parallel to the horizontal plane.AFDS
Longest Horizontal Distance Between Mounting Centers:
4.640 inches
MRC:
The shortest distance between mounting centers parallel to the horizontal plane.AFDT
Shortest Horizontal Distance Between Mounting Centers:
2.320 inches
MRC:
The longest distance between mounting centers parallel to the vertical plane.AFDV
Longest Vertical Distance Between Mounting Centers:
3.530 inches
MRC:
Indicates the type of sensor or transducer used in the item to convert temperature changes to switch actuating force.AKBY
Tempurature Sensing Element Type:
Capillary tube-bulb
MRC:
The means of attaching the item.AXGY
Mounting Method:
Bracket and unthreaded hole
MRC:
The general configuration and relative position of the facilities provided for mounting the item.CQYJ
Mounting Facility Pattern:
Isosceles triangle
MRC:
The designation that identifies the electrical configuration of a nonpile-up contact group including the number of switching poles or forms.CRLD
Nonpile-up Contact Arrangement:
1 pole, double throw, both positions maintained
MRC:
Indicates the type of terminal for providing electrical connection to the item.CSCF
Terminal Type:
Screw
MRC:
The amount of current that the contacts are rated to make or break with a specified load.CTHF
Contact Load Current Rating:
16.0 amperes resistive load first voltage
MRC:
The amount of current that the contacts are rated to make or break with a specified load.CTHF
Contact Load Current Rating:
7.7 amperes resistive load fourth voltage
MRC:
The amount of current that the contacts are rated to make or break with a specified load.CTHF
Contact Load Current Rating:
8.0 amperes resistive load third voltage
MRC:
The amount of current that the contacts are rated to make or break with a specified load.CTHF
Contact Load Current Rating:
9.2 amperes resistive load second voltage
MRC:
The adjustability of the contact.CTYC
Contact Adjustability:
Actuation point adjustable
MRC:
The minimum and maximum limits to which the contact(s) may be adjusted.CTYM
Contact Adjustment Range:
+100.00 to 250.00 actuation point degrees fahrenheit
MRC:
Indicates the type of device provided for manual adjustment of the contact(s).CTYS
Contact Adjustment Type:
Internal actuation point dial
MRC:
The voltage for which the contact(s) is rated at sea level or at a specified altitude,expressed in volts.CTZB
Contact Voltage Rating In Volts:
120.0 ac at sea level first voltage
MRC:
The voltage for which the contact(s) is rated at sea level or at a specified altitude,expressed in volts.CTZB
Contact Voltage Rating In Volts:
208.0 ac at sea level second voltage
MRC:
The voltage for which the contact(s) is rated at sea level or at a specified altitude,expressed in volts.CTZB
Contact Voltage Rating In Volts:
240.0 ac at sea level third voltage
MRC:
The voltage for which the contact(s) is rated at sea level or at a specified altitude,expressed in volts.CTZB
Contact Voltage Rating In Volts:
277.0 ac at sea level fourth voltage
MRC:
The type of media for which the item is designed.MEDA
Media For Which Designed:
Gas or liquid
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the item.STYL
Style Designator:
Rectangular w/mounting lugs

Similar Thermostatic Switches

« Switches Catalog
Compare Now »
Clear | Hide