Part Number A3034807

Reactor

Pricing & Availability

Submit this form for current pricing and availability of this NSN.
Part / NSN:
Qty:
Your Email:
Phone:
Ref. / PO #:
Company:
Your Name:

We do not share or sell your information to anyone.
Privacy | Terms

All major credit cards accepted as well as gov. p-cards
Part Number
DEMIL
Shelf Life
UOM
NIIN
Part:
a3034807
Demil:
No
Shelf Life:
UOM:
NIIN:
013455011
NSN
National Stock Number:
5950-01-345-5011 5950013455011
TXT
Description:
Reactor
INC
INC
Item Name Code:
00724
MRC:
An indication that the level of probability that an item will operate without failure,at a specified rated capability,at a specified temperature,and for a specified period of time,has been established by testing random samples of production lot.AARG
Reliability Indicator:
Not established
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
0.850 inches
MRC:
The number of turns of conductive material forming the winding.ABHY
Turn Quantity:
25 single component single winding
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
0.850 inches
MRC:
Indicates the type of inductance included on the item.ACYF
Inductance Type:
Fixed
MRC:
The value(s) of inductance inherent in the item.ACYV
Inductance Rating:
160.00 microhenries single component single winding
MRC:
A measurement from the bottom to the top of the body,in distinction from depth.ADAU
Body Height:
0.640 inches
MRC:
The maximum temperature at which the item is rated to operate for an extended period of time.AEHZ
Maximum Operating Temp:
155.0 degrees celsius
MRC:
The number of individual /not electrically connected/ windings.AKDX
Winding Quantity:
1 single component
MRC:
Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
Inclosure Type:
Fully enclosed
MRC:
The means of attaching the item.AXGY
Mounting Method:
Terminal single group
MRC:
The means by which the rating is determined.BKPL
Rating Method:
Electrical single component single winding and winding turns single component single winding
MRC:
Those features,not otherwise specified,which may be required for proper functioning of the item.CBBL
Features Provided:
Tinned wire leads
MRC:
The size of the conductor which forms the winding on the item.CQPZ
Winding Conductor Size:
0.03196 inches american wire gage single component single winding
MRC:
The amount of operating current for which the winding is designed.CRBZ
Winding Operating Current:
5.5 amperes dc single component single winding
MRC:
The opposition to the flow of direct current offered by an item,expressed in ohms.CRGS
Dc Resistance Rating In Ohms:
0.025 single component single winding
MRC:
The specification,standard,drawing,or similar instrument that specifies environmental and performance requirements or test conditions under which an item is tested and establishes acceptable limits within which the item must conform identified by an alphabetic and/or numeric reference number. includes the commercial and government entity (cage) code of the entity controlling the instrument.TEST
Test Data Document:
80063-a3034807 drawing (this is the basic governing drawing, such as a contractor drawing, original equipment manufacturer drawing, etc.; excludes any specification, standard or other document that may be referenced in a basic governing drawing)
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
2 wire lead

Similar Reactors

« Coils and Transformers Catalog
Compare Now »
Clear | Hide