Part Number
DEMIL
Shelf Life
UOM
NIIN
NSN
National Stock Number:
TXT
Description:
Alternating Current Motor
MRC:
The distance measured in a straight line from the bottom to the top of an item.AAJT
Overall Height:
4.540 inches
MRC:
A measurement of the longest dimension of an item,in distinction from width.AAJU
Overall Length:
4.875 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.AAJV
Overall Width:
3.080 inches
MRC:
The maximum altitude at which the item is rated to function.AKAE
Maximum Operating Altitude Rating:
65000.0 feet
MRC:
The direction of rotation of a rotating shaft as viewed from the drive end.AKCT
Shaft Rotation Direction:
Clockwise single end or counterclockwise single end
MRC:
The working period under which the item was designed to operate.AKPS
Duty Cycle:
Continuous
MRC:
An indication of the feature/s/ of the inclosure.ANPZ
Inclosure Feature:
Explosion proof
MRC:
Indicates the specific arrangement in which wire is wound on a form or is formed by winding.AXCP
Winding Type:
Induction-squirrel cage
MRC:
The means of attaching the item.AXGY
Mounting Method:
Pad
MRC:
Indicates the type and number of facilities by which the item is mounted.AXHR
Mounting Facility Type And Quantity:
4 unthreaded hole
MRC:
The means of cooling used to maintain the required operating temperature of the item.BFMF
Cooling Method:
Nonventilated
MRC:
The government or industrial specification or standard that defines the inclosure feature.BKPQ
Inclosure Specificationification:
Mil-std-108
MRC:
A designation indicating the frame size by which the item is identified.CNMM
Frame Size Designation:
250
MRC:
The amount of electrical energy that can be dissipated.CNXS
Power Rating:
0.2500 horsepower output
MRC:
A measurement of the longest dimension of the shaft projection of an item,in distinction from width.CWCS
Length Of Shaft From Housing:
0.555 inches single end
MRC:
The temperature at which the item is designed to operate.CWDY
Tempurature Rating:
-55.0 operating degrees celsius and 121.0 operating degrees celsius and 50.0 ambient degrees celsius
MRC:
The speed rating of a rotor,expressed in revolutions per minute.CWFX
Rotor Speed Rating In Rpm:
11500.0 single full load
MRC:
The nominal center to center distance between the mounting facilities parallel to the width.CWFY
Center To Center Distance Between Mounting Facilities Parallel To Width:
2.120 inches
MRC:
The nominal center to center distance between the mounting facilities parallel to the height.CWGD
Center To Center Distance Between Mounting Facilities Parallel To Height:
2.120 inches
MRC:
Indicates the type of connection,rating sequence,and voltage rating at which the item is designed to operate,expressed in volts.CWGQ
Connection Type And Voltage Rating In Volts:
208.0 line to neutral single input
MRC:
An indication of the characteristic(s) of the shaft end.CWHZ
Shaft End Characteristic:
A23 single style single end
MRC:
The number of alternating current phases.FAAZ
Phase:
Three input
MRC:
The cycles per second /hertz/ of the alternating current.FREQ
Frequency In Hertz:
400.0 input
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
1 plug