Part Number
DEMIL
Shelf Life
UOM
NIIN
Part Information
Output voltage analog meter, control selector switch, voltage and current adjustable, local control potentiometer, electrostatic sensitive device
NSN
National Stock Number:
TXT
Description:
Power Supply
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
19.000 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
5.250 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
13.110 inches
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
F-15
MRC:
The relationship of the electrical power source to the item.AKWC
Electrical Power Source Relationship:
Operating
MRC:
The number of input alternating current phase(s).ANPM
Input Phase:
Single 1st alternate operating power rqmt
MRC:
The number of input alternating current phase(s).ANPM
Input Phase:
Single 2nd alternate operating power rqmt
MRC:
The number of input alternating current phase(s).ANPM
Input Phase:
Single 3rd alternate operating power rqmt
MRC:
The number of input alternating current phase(s).ANPM
Input Phase:
Single 4th alternate operating power rqmt
MRC:
The input value/s/,or range of values,for which the item is rated.APNX
Input Voltage Rating:
120.0 ac pounds per hour dry 2nd alternate operating power rqmt and 130.0 ac pounds per hour with retaining chain 2nd alternate operating power rqmt
MRC:
The input value/s/,or range of values,for which the item is rated.APNX
Input Voltage Rating:
220.0 ac pounds per hour dry 3rd alternate operating power rqmt and 230.0 ac pounds per hour with retaining chain 3rd alternate operating power rqmt
MRC:
The input value/s/,or range of values,for which the item is rated.APNX
Input Voltage Rating:
230.0 ac pounds per hour dry 4th alternate operating power rqmt and 250.0 ac pounds per hour with retaining chain 4th alternate operating power rqmt
MRC:
The input value/s/,or range of values,for which the item is rated.APNX
Input Voltage Rating:
90.0 ac pounds per hour dry 1st alternate operating power rqmt and 110.0 ac pounds per hour with retaining chain 1st alternate operating power rqmt
MRC:
The output value/s/,or range of values,for which the item is rated.APPA
Output Voltage Rating:
0.0 dc kilovolts single power output and 30.0 dc kilovolts single power output
MRC:
The number of complete cyclic changes,per unit of time,for which the input is rated.APTQ
Input Frequency Rating:
48.0 hertz 2nd alternate operating power rqmt and 62.0 hertz 2nd alternate operating power rqmt
MRC:
The number of complete cyclic changes,per unit of time,for which the input is rated.APTQ
Input Frequency Rating:
48.0 hertz 1st alternate operating power rqmt and 62.0 hertz 1st alternate operating power rqmt
MRC:
The number of complete cyclic changes,per unit of time,for which the input is rated.APTQ
Input Frequency Rating:
48.0 hertz 4th alternate operating power rqmt and 62.0 hertz 4th alternate operating power rqmt
MRC:
The number of complete cyclic changes,per unit of time,for which the input is rated.APTQ
Input Frequency Rating:
48.0 hertz 3rd alternate operating power rqmt and 62.0 hertz 3rd alternate operating power rqmt
MRC:
The ambient temperature range at which the item is designed to operate.AYNH
Operating Ambient Tempurature Range:
+0.1/+50.0 degrees celsius
MRC:
The master requirement codes of those requirements which are technically critical by reason of tolerance,fit,performance,or other characteristics which affect identification of the item.CRTL
Criticality Code Justification:
Feat
MRC:
The output current rating at which the item is designed to operate.CWGH
Output Current Rating:
0.0 dc milliamperes single power output and 1.5 dc milliamperes single power output
MRC:
Indicates the location of the output control(s).CWHC
Output Control Location:
Rear panel single power output
MRC:
The number of electrical output connections on the item.CWHF
Output Connection Quantity:
1 single power output
MRC:
Indicates the type of electrical output connection.CWHJ
Output Connection Type:
Connector, receptacle single power output
MRC:
The amount of input current for which the item is rated.CWHM
Input Current Rating:
70.0 ac amperes 1st alternate operating power rqmt
MRC:
The amount of input current for which the item is rated.CWHM
Input Current Rating:
70.0 ac amperes 2nd alternate operating power rqmt
MRC:
The amount of input current for which the item is rated.CWHM
Input Current Rating:
70.0 ac amperes 3rd alternate operating power rqmt
MRC:
The amount of input current for which the item is rated.CWHM
Input Current Rating:
70.0 ac amperes 4th alternate operating power rqmt
MRC:
The number of electrical input connections on the item.CWHT
Input Connection Quantity:
1 1st alternate operating power rqmt
MRC:
The number of electrical input connections on the item.CWHT
Input Connection Quantity:
1 2nd alternate operating power rqmt
MRC:
The number of electrical input connections on the item.CWHT
Input Connection Quantity:
1 3rd alternate operating power rqmt
MRC:
The number of electrical input connections on the item.CWHT
Input Connection Quantity:
1 4th alternate operating power rqmt
MRC:
Indicates the type of design provided for ventilation of the item.CWKG
Ventilation Design Type:
Convection